Integrated solid-state wearable sweat sensor system for sodium and potassium ion concentration detection
Authors:
- 13 January 2022
- journal article
- research article
- Published by Emerald Publishing in Sensor Review
- Vol. 42 (1) , 76-88
Abstract
Purpose: Design, fabricate and evaluate all-solid-state wearable sensor systems that can monitor ion concentrations in human sweat to provide real time health analysis and disease diagnosis capabilities. Design/methodology/approach: A human health monitoring system includes disposable customized flexible electrode array and a compact signal transmission-processing electronic unit. Findings: Patterned rGO (reduced-graphene oxide) layers can replace traditional metal electrodes for the fabrication of free-standing all solid film sensors to provide improved flexibility, sensitivity, selectivity, and stability in ion concentration monitoring. Electrochemical measurements show the open circuit potential of current selective electrodes exhibit near Nernst responses versus Na+ and K+ ion concentration in sweat. These signals show great stability during a typical measurement period of 3 weeks. Sensor performances evaluated through real time measurements on human subjects show strong correlations between subject activity and sweating levels, confirming high degree of robustness, sensitivity, reliability and practicality of current sensor systems. Originality/value: In improving flexibility, stability and interfacial coherency of chemical sensor arrays, rGO films have been the developed as a high-performance alternative to conventional electrode with significant cost and processing complexity reduction. rGO supported solid state electrode arrays have been found to have linear potential response versus ion concentration, suitable for electrochemical sensing applications. Current sweat sensor system has a high degree of integration, including electrode arrays, signal processing circuits, and data visualization interfaces.Keywords
This publication has 30 references indexed in Scilit:
- Unobtrusive Sensing and Wearable Devices for Health InformaticsIEEE Transactions on Biomedical Engineering, 2014
- A reference electrode based on polyvinyl butyral (PVB) polymer for decentralized chemical measurementsAnalytica Chimica Acta, 2014
- Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+Advanced Healthcare Materials, 2013
- Electrolyte abnormalities in cystic fibrosis: systematic review of the literaturePediatric Nephrology, 2013
- A review of wearable sensors and systems with application in rehabilitationJournal of NeuroEngineering and Rehabilitation, 2012
- Gold nanoparticles solid contact for ion-selective electrodes of highly stable potential readingsTalanta, 2011
- Direct reduction of graphene oxide films into highly conductive and flexible graphene films by hydrohalic acidsCarbon, 2010
- Solid Contact Potentiometric Sensors for Trace Level MeasurementsAnalytical Chemistry, 2006
- Variations in regional sweat composition in normal human malesExperimental Physiology, 2000
- Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron TransducersAnalytical Chemistry, 1999