Monitoring Flow Rates and Retention of Inhalation Techniques Using the In-Check Dial Device in Adult Asthmatics
Authors:
- Gary K. IwamotoGIGary K. Iwamoto
- Michelle S. HarkinsMHMichelle S. Harkins
- Joseph MorelosJMJoseph Morelos
- 1 January 2007
- journal article
- Published by Taylor & Francis in Journal of Asthma
- Vol. 44 (3) , 209-212
Abstract
The In-Check-Dial (Alliance Tech Medical, Granburg, TX) was used to determine adequacy of inhalation techniques and teaching of two different devices. Retention of adequate techniques, was assessed in 234 moderate to severe asthmatics. Inhalation techniques were assessed at periodic follow-ups divided into less than 1 month return visit, between 1 and 3 months, 3 to less than 6 months, and 6 months to less than 1 year. Proper inhalation techniques worsened at greater than 3 months after the last instruction. The use of the In-Check-Dial is a useful tool in teaching proper technique and monitoring the patient's ability to correctly use inhalation devices.Keywords
This publication has 14 references indexed in Scilit:
- Assessment of inhalation technique and determinants of incorrect performance among children with asthmaPediatric Pulmonology, 2006
- Proficiency of Pediatricians in the Use of Inhaled Medication Delivery Systems for the Management of AsthmaJournal of Asthma, 2006
- Measurement of peak inspiratory flow with in-check dial device to simulate low-resistance (Diskus) and high-resistance (Turbohaler) dry powder inhalers in children with asthmaPediatric Pulmonology, 2005
- Monitoring Pulmonary Function in Asthma and COPD: Point-of-Care TestingAnnals of Pharmacotherapy, 2004
- Peak inspiratory flow through Diskus and Turbuhaler, measured by means of a peak inspiratory flow meter (In-Check DIAL®)Respiratory Medicine, 2003
- Is inhalation rate important for a dry powder inhaler? using the In-Check Dial to identify these ratesRespiratory Medicine, 2003
- Treatment failures in children with asthma due to inappropriate use of turbuhalerThe Journal of Pediatrics, 2002
- Pico de flujo inspiratorio de dos inhaladores diferentes con un nuevo aparato portátilAnales de Pediatría, 2001
- Washing plastic spacers in household detergent reduces electrostatic charge and greatly improves deliveryEuropean Respiratory Journal, 1999
- A Critical Comparison of the Dose Delivery Characteristics of Four Alternative Inhalation Devices Delivering Salbutamol: Pressurized Metered Dose Inhaler, Diskus Inhaler, Diskhaler Inhaler, and Turbuhaler InhalerJournal of Aerosol Medicine, 1999