Abstract
One contrastive research on two stator partitioned doubly salient permanent magnet (PS-DSPM) machines is performed in this essay. The machines have disparate numbers of permanent magnets (PMs) and rotor iron pieces. The conventional numbers of PMs and rotor iron pieces are 4 and 8 while the newly proposed numbers of PMs and rotor iron pieces are 6 and 7. As for an objective contrast, both PSDSPM machines investigated here are optimized for the purpose of attaining a larger average torque based on single-variable optimizing approach under the fixed envelope size and copper loss. Furthermore, several main electromagnetic characteristics of two PS-DSPM machines are contrasted, such as no-load flux linkage, back-electromotive force (back-EMF), torque capability, alongside cogging torque. The comparison consequences illustrate that compared to the PS-DSPM machine with conventional 4 PMs and 8 rotor iron blocks, the PS-DSPM machine with proposed 6 PMs and 7 rotor iron blocks increases average torque by 5.4% and the torque ripple drops dramatically by 149.47%.

This publication has 8 references indexed in Scilit: