Accuracy of non-invasive body temperature measurement methods in critically ill patients: a prospective, bicentric, observational study
Open Access
- 1 September 2021
- journal article
- research article
- Published by Elsevier in Critical Care and Resuscitation
- Vol. 23 (3) , 346-353
Abstract
Objective: The accuracy of different non-invasive body temperature measurement methods in intensive care unit (ICU) patients is uncertain. We aimed to study the accuracy of three commonly used methods. Design: Prospective observational study. Setting: ICUs of two tertiary Australian hospitals. Participants: Critically ill patients admitted to the ICU. Interventions: Invasive (intravascular and intra-urinary bladder catheter) and non-invasive (axillary chemical dot, tympanic infrared, and temporal scanner) body temperature measurements were taken at study inclusion and every 4 hours for the following 72 hours. Main outcome measures: Accuracy of non-invasive body temperature measurement methods was assessed by the Bland-Altman approach, accounting for repeated measurements and significant explanatory variables that were identified by regression analysis. Clinical adequacy was set at limits of agreement (LoA) of 1 degrees C compared with core temperature. Results: We studied 50 consecutive critically ill patients who were mainly admitted to the ICU after cardiac surgery. From over 375 observations, invasive core temperature (mostly pulmonary artery catheter) ranged from 33.9 degrees C to 39 degrees C. On average, the LoA between invasive and non-invasive measurements methods were about 3 degrees C. The temporal scanner showed the worst performance in estimating core temperature (bias, 0.66 degrees C; LoA, -1.23 degrees C, +2.55 degrees C), followed by tympanic infrared (bias, 0.44 degrees C; LoA, -1.73 degrees C, +2.61 degrees C) and axillary chemical dot methods (bias, 0.32 degrees C; LoA, -1.64 degrees C, +2.28 degrees C). No methods achieved clinical adequacy even accounting for significant explanatory variables. Conclusions: The axillary chemical dot, tympanic infrared and temporal scanner methods are inaccurate measures of core temperature in ICU patients. These non-invasive methods appeared unreliable for use in ICU patients.Keywords
This publication has 36 references indexed in Scilit:
- Noninvasive Measurement of Body Temperature in Critically Ill PatientsCritical Care Nurse, 2009
- Temperature Monitoring and Perioperative ThermoregulationAnesthesiology, 2008
- Guidelines for evaluation of new fever in critically ill adult patients: 2008 update from the American College of Critical Care Medicine and the Infectious Diseases Society of AmericaCritical Care Medicine, 2008
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- Tympanic temperature measurements: Are they reliable in the critically ill? A clinical study of measures of agreement*Critical Care Medicine, 2007
- Temperature measurement: comparison of non‐invasive methods used in adult critical careJournal of Clinical Nursing, 2005
- Comparison of ear-based, bladder, oral, and axillary methods for core temperature measurementCritical Care Medicine, 1993
- Core temperature measurement in the intensive care unitCritical Care Medicine, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- COMPARISON OF INTRACARDIAC AND INTRAVASCULAR TEMPERATURES WITH RECTAL TEMPERATURES IN MAN 12Journal of Clinical Investigation, 1951