Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty
Authors:
- 13 February 2009
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 34 (1) , 19-26
Abstract
We analysed data from 155 revisions of identical cementless hip prostheses to determine the influence of patient-, implant- and surgery-related factors on the polyethylene wear rate and size of periprosthetic osteolysis (OL). This was calculated by logistic regression analysis. Factors associated with an increased/decreased wear rate included position of the cup relative to Kohler’s line, increase in abduction angle of the cup, traumatic and inflammatory arthritis as a primary diagnosis, and patient height. Severe acetabular bone defects were predicted by an increased wear rate (odds ratio, OR = 5.782 for wear rate above 200 mm3/y), and increased height of the patient (OR = 0.905 per each centimetre). Predictors of severe bone defects in the femur were the increased wear rate (OR = 3.479 for wear rate above 200 mm3/y) and placement of the cup outside of the true acetabulum (OR = 3.292). Variables related to surgical technique were the most predictive of polyethylene wear rate.Keywords
This publication has 50 references indexed in Scilit:
- Influence of the acetabular cup position on hip load during arthroplasty in hip dysplasiaInternational Orthopaedics, 2008
- The lexicon of polyethylene wear in artificial jointsBiomaterials, 2007
- Distinct Inflammatory Gene Pathways Induced by ParticlesClinical Orthopaedics and Related Research, 2007
- Wear analysis of failed acetabular polyethyleneThe Journal of Bone and Joint Surgery. British volume, 2007
- Avoiding misclassification bias with the traditional Charnley classification: Rationale for a fourth Charnley class BBJournal of Orthopaedic Research, 2006
- Polyethylene wear rate and osteolysis: Critical threshold versus continuous dose-response relationshipJournal of Orthopaedic Research, 2005
- High osteolysis and revision rate with the hydroxyapatite-coated ABG hip prostheses65 hips in 56 young patients followed for 5–9 yearsActa Orthopaedica, 2004
- High survival rate of hydroxyapatite-coated hip prostheses100 consecutive hips followed for 10 yearsActa Orthopaedica, 2004
- Wear Is a Function of Use, Not TimeClinical Orthopaedics and Related Research, 2000
- A 12??? to 18-Year Radiographic Follow-Up Study of Charnley Low-Friction ArthroplastyClinical Orthopaedics and Related Research, 1993