Abstract
Very precise combined work between multidisciplinary partners (radiation engineers in physics, engineers in biomechanics, medical radiologists and orthopedic pediatric surgeons) has led to the concept and development of a new low-dose radiation device named EOS. This device has three main advantages: (1) Thanks to the invention of Georges Charpak who designed gaseous detectors for X-rays, the reduction of dose necessary to obtain a good image of skeletal system was 8 to 10 times less for 2D imaging; compared to the dose necessary to obtain a 3D reconstruction from CT scan cuts, the reduction factor was 800 to 1000. (2) The accuracy of 3D reconstruction obtained is better than that of 3D reconstruction from CT scan cuts. (3) The patient in addition gets imaged in a standing functional position, thanks to the AP and lateral X-rays obtained from head to feet simultaneously. This is a big advantage compared to CT scans which are used only in lying position. From the simultaneous AP and lateral X-rays of the whole body obtained via the 3D bone external envelop technique, the biomechanics engineers obtain 3D reconstruction of every level of osteo-articular system, especially for spine, in standing position with an acceptable period of time for reconstruction. This (in spite of the evolution of standing MRI) allows more precise bone reconstruction in orthopedics, especially at the level of the entire skeleton, including the head, spine, pelvis, lower limbs, giving new consideration for physiology, physiopathology and therapeutics.Keywords
This publication has 7 references indexed in Scilit:
- Fast accurate stereoradiographic 3D-reconstruction of the spine using a combined geometric and statistic modelClinical Biomechanics, 2004
- Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countriesThe Lancet, 2004
- The new effective detector for digital scanning radiographyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Three-dimensional (3D) detailed reconstruction of human vertebrae from low-dose digital stereoradiographyEuropean Journal of Orthopaedic Surgery & Traumatology, 2003
- A Biplanar Reconstruction Method Based on 2D and 3D Contours: Application to the Distal FemurComputer Methods in Biomechanics and Biomedical Engineering, 2003
- 3D reconstruction method from biplanar radiography using non-stereocorresponding points and elastic deformable meshesMedical & Biological Engineering & Computing, 2000
- Evaluation of a new low-dose digital X-ray device: first dosimetric and clinical results in childrenPediatric Radiology, 1998