Vancomycin elution kinetics from porous tantalum metal
- 8 February 2019
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 37 (2) , 308-312
Abstract
Revisions TKAs are being completed with uncemented constructs more frequently. We hypothesized that tantalum cones could be an efficient carrier of antibiotics in uncemented procedures. We aimed to compare the release of vancomycin between 1) tantalum and smooth stainless cylinders, 2) different concentrations of vancomycin and 3) different durations of bathing. Specifically designed tantalum cylinders were bathed in a vancomycin solution with various durations of baths. We investigated rinses between each interval as well as the dose of vancomycin. Vancomycin concentrations were determined in each group by fluorescence polarization immunoassay at different intervals (1 hour, days 1, 2, 3, 5). At 1 hour, the mean vancomycin concentration for the one‐hour soaking group was 3172 µg/mL, whereas mean concentration for the smooth stainless steel group was 39.37 µg/mL (p < 0.001). The rinsing group showed a significantly lower concentration at 1 hour and 1 day (p < 0.05). The 2‐gram vancomycin group showed no difference at days 1, 2 and 3 compared to the 1‐hour group. The 5, 15 and 30‐minute bathing groups showed significantly lower vancomycin concentrations at all‐time points. All vancomycin concentrations at day 3 were superior to the minimal inhibitory concentration of Staphyloccocus aureus. The mean concentration of vancomycin depends on the material, duration of bathing, the rinsing effect, and the drug dose. Our in‐vitro study is the first to show that porous tantalum cylinders allow antibiotic carriage and progressive release. If appearing in‐vivo, in a similar extent, this intrinsic property might be useful to prevent and/or treat peri‐prosthetic joint infection. This article is protected by copyright. All rights reservedKeywords
This publication has 26 references indexed in Scilit:
- Early Results of the Use of Tantalum Femoral Cones for Revision Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2011
- Use of Porous Tantalum Metaphyseal Cones for Severe Tibial Bone Loss During Revision Total Knee ReplacementJournal of Bone and Joint Surgery, 2008
- Antibiotics for Local Delivery Systems Cause Skeletal Cell Toxicity In VitroClinical Orthopaedics and Related Research, 2007
- Primary human osteoblasts grow into porous tantalum and maintain an osteoblastic phenotypeJournal of Biomedical Materials Research Part A, 2007
- In Vitro Elution of Vancomycin from Calcium Phosphate CementThe Journal of Arthroplasty, 2005
- Local Antibiotic Delivery SystemsClinical Orthopaedics and Related Research, 2005
- Effective bactericidal activity of tobramycin and vancomycin eluted from acrylic bone cementActa Orthopaedica, 2001
- Infected Tibial Nonunions (1981-1995)Clinical Orthopaedics and Related Research, 1999
- Elution characteristics of vancomycin and tobramycin combined in acrylic bone—cementThe Journal of Arthroplasty, 1996
- The release in vitro of vancomycin and tobramycin from acrylic bone cementJournal of Antimicrobial Chemotherapy, 1994