ARTHROSCOPIC REMOVAL OF ACRYLIC CEMENT FROM UNREDUCED HIP PROSTHESIS
Authors:
- 1 June 1992
- journal article
- Published by Wiley in Anz Journal of Surgery
- Vol. 62 (6) , 508-510
Abstract
A case is reported in which entrapped polymethylmethacrylate following traumatic dislocation of a total hip replacement prevented complete reduction. A combined arthroscopic and fluoroscopic technique was used to remove the entrapped polymethylmethacrylate. Manipulation of the total hip prosthesis was done after removal of polymethylmethacrylate to minimize mechanical abrasion. This technique allows direct visual assessment of the articulating surfaces as well as the mechanical stability of the prosthesis. The morbidity related to the procedure is minimal and a short rehabilitation period is the major advantage.Keywords
This publication has 7 references indexed in Scilit:
- Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results.Journal of Bone and Joint Surgery, 1990
- Failure of bipolar hip arthroplasty secondary to retained antibiotic-impregnated polymethylmethacrylate beads. A case report.Journal of Bone and Joint Surgery, 1988
- A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles.Journal of Bone and Joint Surgery, 1988
- A Posterior Arthroscopic Approach to Bullet Extraction from the Hip1987
- Hip arthroscopy by the lateral approachArthroscopy, 1987
- Diagnostic and Operative Arthroscopy of the HipOrthopedics, 1986
- Entrapped Foreign Body Within the Acetabular Cup in Total Hip ReplacementClinical Orthopaedics and Related Research, 1980