Prefabricated zirconium dioxide implant abutments for single‐tooth replacement in the posterior region: evaluation of peri‐implant tissues and superstructures after 12 months of function
Authors:
- 7 July 2010
- journal article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 21 (8) , 857-865
Abstract
Aim: In the present study, prefabricated abutments made of zirconium dioxide Y‐TZP (tetragonal zirconia polycrystals) were inserted into the posterior region under controlled clinical conditions. The aim was to test whether abutments made of zirconium dioxide are suitable for this indication. Investigation parameters included reactions of peri‐implant tissue and the structural integrity of the all‐ceramic superstructures on the implants. Results after 12 months in function are reported in this article.Material and methods: Forty implants of the XiVE® S plus screw‐type implants (DENTSPLY Friadent) were inserted into the posterior region of 24 patients. After the healing period, the implants were provided with all‐ceramic abutments made of zirconium dioxide Y‐TZP (FRIADENT® CERCON® Abutment; DENTSPLY Friadent). All‐ceramic crowns (CERCON® smart ceramics; DENTSPLY DeguDent) were used as superstructures and cemented using the conventional method. The following parameters were used to document the state of soft tissue: modified plaque index (mPI), sulcus fluid flow rate (SFFR, Periotron; Oraflow Inc), modified sulcus bleeding index (mSBI) and pocket depth (ST). Mesial and distal bone levels were determined on radiographs during the prosthetic treatment and at the 12‐month recall. The Periotest™ (Medizintechnik Gulden) was used to determine implant stability.Results: All implants could be followed up after 12 months in function. In the presence of good oral hygiene (mPI: 0.5), the parameters SFFR (18) and mSBI (0.5) were indicative of stable and healthy soft tissue. ST was highest at the distal points of measurement (2.3 mm) and was generally at a low level. Compared with the baseline situation, proximal bone defects were reduced from −1.1 to −1 mm during the 12‐month period of functioning. The mean Periost™ values at the 12‐month recall were −1.9 in the maxilla and −3.8 in the mandible. Neither implant loss nor crown fractures occurred. Chipping of parts of the veneering ceramic was registered in four cases (10%).Conclusion: After 12 months of wear, no mechanical failure was registered in any of the all‐ceramic abutments. On clinical investigation, the peri‐implant hard and soft tissues were largely healthy and devoid of inflammation. To cite this article: Nothdurft F, Pospiech P. Prefabricated zirconium dioxide implant abutments for single‐tooth replacement in the posterior region: evaluation of peri‐implant tissues and superstructures after 12 months of function. Clin. Oral Impl. Res. 21, 2010; 857–865. doi: 10.1111/j.1600‐0501.2009.01899.xKeywords
This publication has 29 references indexed in Scilit:
- Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs)Clinical Oral Investigations, 2009
- Fracture force of tooth–tooth‐ and implant–tooth‐supported all‐ceramic fixed partial dentures using titanium vs. customised zirconia implant abutmentsClinical Oral Implants Research, 2008
- The mucosal barrier at implant abutments of different materialsClinical Oral Implants Research, 2008
- Immediate provisional restoration of XiVE® screw‐type implants in the posterior mandibleClinical Oral Implants Research, 2007
- A 10‐year prospective study of ITI dental implants placed in the posterior region. I: Clinical and radiographic resultsClinical Oral Implants Research, 2007
- Fracture resistance of single‐tooth implant‐supported all‐ceramic restorations after exposure to the artificial mouthJournal of Oral Rehabilitation, 2006
- Mandibular two‐implant telescopic overdenturesClinical Oral Implants Research, 2004
- A Bone Quality–Based Implant System: First Year of Prosthetic LoadingJournal of Oral Implantology, 1999
- Long‐term evaluation of non‐submerged ITI implants. Part 1: 8‐year life table analysis of a prospective multi‐center study with 2359 implants.Clinical Oral Implants Research, 1997
- The microbiota of osseointegrated implants in patients with a history of periodontal diseaseJournal of Clinical Periodontology, 1995