The principal interactions between melting current, self-generated magnetic fields, and structural parts of the vacuum arc furnace, and the effect of unsymmetrical stray fields on arc characteristics, pool behavior, and metallurgical quality are briefly reviewed. Various macrosegregation defects are caused by unbalanced electromagnetic interactions affecting pool rotation and the solidification process. The procedure for measuring magnetic-flux density is described, and the results obtained on a large vacuum arc furnace with different bus-bar arrangements are presented. These results, along with extensive operational observations, strongly pointed out the importance of properly located current connections and coaxial current flow on furnace operation and ingot quality. Corrective actions and modifications of the current transmission system to eliminate nonuniform magnetic stray fields from the arc and melting zone are outlined. A coaxial, electromagnetically “clean” configuration of the entire current circuit to and within the furnace is a most important requirement for consistent consumable-electrode melting operation and reliable avoidance of macrosegregations in specialty steels and alloys. A discussion of controlling electromagnetic interactions by careful engineering of the current supply layout and incorporation of these concepts into an advanced furnace design concludes the paper.