Allogeneic donor peripheral blood “stem cell” apheresis: prospective comparison of two apheresis systems
Authors:
- 2 November 2011
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 52 (5) , 1137-1145
Abstract
BACKGROUND: Granulocyte–colony‐stimulating factor–mobilized peripheral blood stem cells, collected by white blood cell apheresis, are used for more than 80% of allogeneic and most autologous hematopoietic stem cell transplantations. Optimal donor and recipient outcomes require maximized stem cell collection efficiency and minimized non–target cell contamination. Therefore, improved apheresis technology is desirable. The safety and feasibility of apheresis collections with the novel, electronics‐assisted apheresis system Spectra Optia v.5.0 (CaridianBCT) were recently demonstrated. An unpublished optimization trial had furthermore determined that different settings than manufacturer‐installed default might result in improved apheresis yields.STUDY DESIGN AND METHODS: The first prospective comparison of allogeneic peripheral blood stem cell apheresis with the Spectra Optia versus the COBE Spectra (CaridianBCT) mononuclear cell (MNC) in a routine clinical setting is reported here; “optimized” machine settings were used. Assessed variables included collection efficiency, product characteristics, donor outcomes, and frequency of operator interventions. Outcomes were additionally compared with historical data from the Spectra Optia in default mode.RESULTS: The mean CD34+ cell collection efficiency CE1 was 7.9% greater with the Spectra Optia than with the COBE Spectra MNC. Variability of outcomes was equally great. Reduced platelet (PLT) attrition necessitated 90% fewer autologous PLT reinfusions. Spectra Optia products contained 50% fewer red blood cells, but 50% more granulocytic lineage cells. Less operator input was required, although 26% of Spectra Optia apheresis procedures required triggering of the first chamber flush. Apheresis yield and collection efficiency were also markedly greater than in default‐mode Spectra Optia collections.CONCLUSION: Using optimized machine settings, peripheral blood stem cell apheresis outcomes with the automated apheresis system Spectra Optia exceed results with the COBE Spectra MNC or the Spectra Optia in the default mode.Keywords
This publication has 35 references indexed in Scilit:
- Safety and efficacy of hematopoietic stem cell collection from mobilized peripheral blood in unrelated volunteers: 12 years of single-center experience in 3928 donorsBlood, 2009
- Severe events in donors after allogeneic hematopoietic stem cell donationHaematologica, 2009
- Haematopoietic stem cell donor registries: World Marrow Donor Association recommendations for evaluation of donor healthBone Marrow Transplantation, 2008
- Change in stem cell source for hematopoietic stem cell transplantation (HSCT) in Europe: a report of the EBMT activity survey 2003Bone Marrow Transplantation, 2005
- Mathematical model of peripheral blood stem cell harvest kineticsBone Marrow Transplantation, 2003
- Inverse relationship between patient peripheral blood CD34+ cell counts and collection efficiency for CD34+ cellsin two automated leukapheresis systemsTransfusion, 2001
- Kinetic studies during peripheral blood stem cell collection show CD34+ cell recruitment intra‐apheresisJournal of Clinical Apheresis, 2001
- A randomized comparison of once versus twice daily recombinant human granulocyte colony‐stimulating factor (filgrastim) for stem cell mobilization in healthy donors for allogeneic transplantationBritish Journal of Haematology, 2000
- Comparison between once a day vs twice a day G-CSF for mobilization of peripheral blood progenitor cells (PBPC) in normal donors for allogeneic PBPC transplantationBone Marrow Transplantation, 1998
- Preapheresis peripheral blood CD34+ mononuclear cell counts as predictors of progenitor cell yieldTransfusion, 1997