Microbial Indoor Air Quality and Associated Factors in Jimma Town Prison Administration, Southwestern Ethiopia
Authors:
Open Access
- 19 August 2022
- journal article
- research article
- Published by SAGE Publications in Environmental Health Insights
- Vol. 16
Abstract
Indoor air quality determines the well-being of occupants. It has been linked to sick building syndrome and building-related diseases which lead to many socio-economic problems including reduced productivity and impaired learning. Indoor air quality problem is more serious for prisoners, due to their confinement and exposure condition. However, it has not been studied in our study setting. Thus, this study aimed to determine the indoor air microbial quality and associated factors in Jimma town prison administration, Southwestern Ethiopia. A cross-sectional study design was employed in August 2021. Data on the general condition of the prison rooms and occupancy were collected by trained data collectors using an observational checklist. The microbial sample was collected using a sterilized Petri dish. A total of 19 triplicate air samples were collected using Mannitol salt agar and Sabouroad dextrose agar media for the growth of S. aureus and fungi respectively. Data were analyzed using SPSS version 23 and presented using tables and a graph. The effect of predictor variables on the microbial load was also analyzed by using linear regression. The finding of this study revealed that the microbial load of indoor air at Jimma town prison administration ranged from 891 to 15 439 and 315 to 3067 CFU/m³ for S. aureus and fungi respectively. Both S. aureus and the fungal load of the indoor environment were positively affected by the temperature of the room. Whereas, the floor space per inmate affects the concentration of S. aureus alone. Almost all rooms of the prison administration had microbial load beyond the acceptable limit. Higher temperature, less floor space per inmate, bad floor cleanness conditions, inadequate ventilation, and dampness were contributing factors to the high load of S. aureus and fungus. Thus, additional rooms are required to reduce overcrowding and keep room temperature.Keywords
This publication has 23 references indexed in Scilit:
- High bacterial load of indoor air in hospital wards: the case of University of Gondar teaching hospital, Northwest EthiopiaMultidisciplinary Respiratory Medicine, 2016
- Milk production, quality, and consumption in Jimma (Ethiopia): Facts and producers’, retailers’, and consumers’ perspectivesPreventive Veterinary Medicine, 2016
- Review of bioaerosols in indoor environment with special reference to sampling, analysis and control mechanismsEnvironment International, 2015
- Quantitative Assessment of Bio-Aerosols Contamination in Indoor Air of University Dormitory RoomsInternational Journal of Health Sciences (Qassim), 2015
- Microbiological assessment of indoor air of teaching hospital wards: A case of Jimma University Specialized HospitalEthiopian Journal of Health Sciences, 2015
- Microbiological Quality of Indoor Air in University LibrariesAsian Pacific Journal of Tropical Biomedicine, 2014
- Respiratory health and indoor air pollutants based on quantitative exposure assessmentsEuropean Respiratory Journal, 2012
- Assessment of airborne bacteria and fungi in an indoor and outdoor environmentInternational Journal of Environmental Science and Technology, 2010
- Inadequate housing and health: an overviewInternational Journal of Environment and Pollution, 2007
- Indoor air quality—bioaerosol measurements in domestic and office premisesJournal of Aerosol Science, 2005