Data processing in Fourier transform ion cyclotron resonance mass spectrometry
- 8 January 2014
- journal article
- review article
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 33 (5) , 333-352
Abstract
The Fourier transform ion cyclotron resonance (FT‐ICR) mass spectrometer intricately couples advanced physics, instrumentation, and electronics with chemical and particularly biochemical research. However, general understanding of the data processing methodologies used lags instrumentation, and most data processing algorithms we are familiar with in FT‐ICR are not well studied; thus, professional skill and training in FT‐ICR operation and data analysis is still the key to achieve high performance in FT‐ICR. This review article is focused on FT‐ICR data processing, and explains the procedures step‐by‐step for users with the goal of maximizing spectral features, such as mass accuracy, resolving power, dynamic range, and detection limits. © 2014 Wiley Periodicals, Inc. Mass Spec Rev 33: 333–352, 2014Keywords
This publication has 108 references indexed in Scilit:
- Absorption‐mode spectra on the dynamically harmonized Fourier transform ion cyclotron resonance cellRapid Communications in Mass Spectrometry, 2012
- Variation of the Fourier Transform Mass Spectra Phase Function with Experimental ParametersAnalytical Chemistry, 2011
- The spontaneous loss of coherence catastrophe in fourier transform ion cyclotron resonance mass spectrometryJournal of the American Society for Mass Spectrometry, 2009
- Artifacts in Fourier transform mass spectrometryRapid Communications in Mass Spectrometry, 2009
- Experimental evidence for space-charge effects between ions of the same mass-to-charge in Fourier-transform ion cyclotron resonance mass spectrometryInternational Journal of Mass Spectrometry, 2007
- Parts-Per-Billion Mass Measurement Accuracy Achieved through the Combination of Multiple Linear Regression and Automatic Gain Control in a Fourier Transform Ion Cyclotron Resonance Mass SpectrometerAnalytical Chemistry, 2007
- Statistical Evaluation of Internal and External Mass Calibration Laws Utilized in Fourier Transform Ion Cyclotron Resonance Mass SpectrometryAnalytical Chemistry, 2005
- Peer Reviewed: Scaling MS Plateaus with High-Resolution FT-ICRMSAnalytical Chemistry, 2002
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998
- Making use of information contained in folded-back peaks to identify low mass ions in Fourier transform mass spectrometryAnalytical Chemistry, 1986