Characterization and Pumping
Authors:
- 1 January 2006
- journal article
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 153 (12) , E185
Abstract
By adding redox species, both aqueous and nonaqueous solutions can be pumped along the length of a microfluidic channel when low voltages (to produce current) are applied across the channel’s breadth in the presence of a magnetic field applied across its height. Control of flow rate is possible by varying the magnitudes of the voltage and magnetic field and by changing the redox concentration. Direction is determined by the voltage polarity and magnetic field orientation. We have demonstrated a dc redox magnetohydrodynamic (MHD) pump in microchannels ( 270μm270μm wide ×640μm×640μm deep ×2cm×2cm long) that were constructed from low-temperature cofired ceramics with screen-printed gold electrodes on opposing sidewalls. Redox MHD involves the generation of current between the electrodes in a solution through the oxidation/reduction of redox species in the presence of a magnetic field. When the current and magnetic fields are perpendicular, a Lorentz force results, causing fluid flow along the length of the channel. The pumping performance was investigated as a function of type and concentration of redox species, magnetic flux density, applied voltage, and time scale. Studies show bidirectional capability by changing the direction of the current. Flow velocities of up to 5.0mm∕s5.0mm∕s were observed in a solution of 0.5M0.5M nitrobenzene (NB) and 0.5M0.5M tetrabutylammonium hexafluorophosphate (TBAPF6)(TBAPF6) in acetonitrile using a 0.41TNdFeB0.41TNdFeB permanent magnet, at an applied voltage of −1.3V−1.3V vs Ag∕AgClAg∕AgCl (saturated KClKCl ) (approximately a potential difference of 1.2–1.7V1.2–1.7V between wall electrodes in the microchannel) and the corresponding current enhancements (caused by the increased convection) were as large as 145%. Flow rates for 0.1M0.1M NB and 0.25M0.25M NB in 0.1MTBAPF60.1MTBAPF6 in acetonitrile were measured at three different applied voltages near the redox potential of NB. Comparisons were also made to theory. A mixture of oxidized and reduced forms of the same redox couple, instead of a single species like NB, can avoid electrode dissolution at the oxidizing electrode (or bubble generation at either electrode). One example of this approach involves a solution of 0.125MFe2+0.125MFe2+ and 0.125MFe3+0.125MFe3+ in 3.0MKCl3.0MKCl and another involves a solution of 0.125MFe(CN)63−0.125MFe(CN)63− and 0.125MFe(CN)64−0.125MFe(CN)64− in 2.0MKCl2.0MKCl , where potential differences between wall electrodes in the microchannel can be less than 0.4V0.4V . Findings from these studies should be useful in development of sealed microanalytical devices using redox MHD pumps with possible lab-on-a-chip applications.Keywords
This publication has 40 references indexed in Scilit:
- A magnetic microstirrer and array for microfluidic mixingJournal of Microelectromechanical Systems, 2002
- Application of magnetohydrodynamic actuation to continuous flow chemistryElectronic supplementary information (ESI) available: figures depicting a silicon MHD microreactor, finite element solution for velocity profile in the silicon microreactor annulus, and the effect of MHD actuation conditions on the PCR product previously generated by conventional amplification methods and on the PCR reagents prior to thermocycling by conventional methods. See http://www.rsc.org/suppdata/lc/b2/b206756k/Lab on a Chip, 2002
- Chaotic Mixer for MicrochannelsScience, 2002
- A minute magneto hydro dynamic (MHD) mixerSensors and Actuators B: Chemical, 2001
- Fabrication and characterization of electroosmotic micropumpsSensors and Actuators B: Chemical, 2001
- An AC magnetohydrodynamic micropumpSensors and Actuators B: Chemical, 2000
- Theoretical and experimental study of MHD (magnetohydrodynamic) micropumpSensors and Actuators A: Physical, 2000
- Handling of Picoliter Liquid Samples in a Poly(dimethylsiloxane)-Based Microfluidic DeviceAnalytical Chemistry, 1999
- Microfabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic AssaysAnalytical Chemistry, 1999
- Microcavities Containing Individually Addressable Recessed Microdisk and Tubular Nanoband ElectrodesJournal of the Electrochemical Society, 1999