Dynamic Cerebral Autoregulation Reproducibility Is Affected by Physiological Variability
Open Access
- 9 July 2019
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 865
Abstract
Parameters describing dynamic cerebral autoregulation (DCA) have limited reproducibility. In an international, multi-center study, we evaluated the influence of multiple analytical methods on the reproducibility of DCA. Fourteen participating centers analyzed repeated measurements from 75 healthy subjects, consisting of 5 min of spontaneous fluctuations in blood pressure and cerebral blood flow velocity signals, based on their usual methods of analysis. DCA methods were grouped into three broad categories, depending on output types: (1) transfer function analysis (TFA); (2) autoregulation index (ARI); and (3) correlation coefficient. Only TFA gain in the low frequency (LF) band showed good reproducibility in approximately half of the estimates of gain, defined as an intraclass correlation coefficient (ICC) of >0.6. None of the other DCA metrics had good reproducibility. For TFA-like and ARI-like methods, ICCs were lower than values obtained with surrogate data (p < 0.05). For TFA-like methods, ICCs were lower for the very LF band (gain 0.38 ± 0.057, phase 0.17 ± 0.13) than for LF band (gain 0.59 ± 0.078, phase 0.39 ± 0.11, p ≤ 0.001 for both gain and phase). For ARI-like methods, the mean ICC was 0.30 ± 0.12 and for the correlation methods 0.24 ± 0.23. Based on comparisons with ICC estimates obtained from surrogate data, we conclude that physiological variability or non-stationarity is likely to be the main reason for the poor reproducibility of DCA parameters.Keywords
This publication has 48 references indexed in Scilit:
- Dynamic cerebral autoregulation: different signal processing methods without influence on results and reproducibilityMedical & Biological Engineering & Computing, 2010
- Reliability of dynamic cerebral autoregulation measurement using spontaneous fluctuations in blood pressureClinical Science, 2009
- Cerebral Autoregulation: An Overview of Current Concepts and Methodology with Special Focus on the ElderlyJournal of Cerebral Blood Flow & Metabolism, 2008
- Cerebral Autoregulation: From Models to Clinical ApplicationsCardiovascular Engineering, 2007
- High spontaneous fluctuation in arterial blood pressure improves the assessment of cerebral autoregulationPhysiological Measurement, 2005
- Changes in Linear Dynamics of Cerebrovascular System After Severe Traumatic Brain InjuryStroke, 2003
- Transfer function analysis for clinical evaluation of dynamic cerebral autoregulation a comparison between spontaneous and respiratory-induced oscillationsPhysiological Measurement, 2002
- Comparison of Static and Dynamic Cerebral Autoregulation MeasurementsStroke, 1995
- Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology.Psychological Assessment, 1994
- Cerebral autoregulation dynamics in humans.Stroke, 1989