Abstract
The purpose of this paper is to demonstrate the importance of a compliant wall approach in modeling of non‐Newtonian and non‐physiological blood flows. A case study of a stenosed and symptomatic carotid bifurcation was considered to show the influence of the wall‐resilience assumption on the flow parameters obtained with numerical simulations. Patient‐specific data concerning the geometry and flow conditions were collected and used to carry out two‐way coupled fluid structure interaction simulations of the pulsatile blood flow through carotid artery. The wall compliance was considered separately as related to the wall‐elasticity and as associated with the reaction of the loose connective tissue surrounding the carotid bifurcation. The obtained hemodynamic parameters were compared to those which were found in rigid‐wall simulations. The difference between the results obtained for rigid‐wall and compliant‐wall approaches for the peak‐systolic area‐averaged wall shear stress achieved 35%, whereas the difference between the time‐averaged local vorticity and shear strain reached, respectively, 42% and 43%. The influence of the highly resilient wall on the monitored hemodynamic parameters was significant even if time‐averaged values are compared, which suggests that these metrics are considerably overestimated if the wall compliance is not considered. Moreover, the findings show that the mechanical response of the loose connective tissue cannot be neglected in blood flow simulations. Additionally, this study indicates that stiffening of the arterial wall due to atherosclerosis significantly rises hemodynamic parameters. This explains the therapeutic benefits of surgical removal of plaque lesions formed in the carotid bifurcation (endarterectomy).Keywords
This publication has 48 references indexed in Scilit:
- Effects of Disturbed Flow on Vascular Endothelium: Pathophysiological Basis and Clinical PerspectivesPhysiological Reviews, 2011
- Numerical simulations of the blood flow through vertebral arteriesJournal of Biomechanics, 2010
- Procedure for Estimation and Reporting of Uncertainty Due to Discretization in CFD ApplicationsJournal of Fluids Engineering, 2008
- Role of Endothelial Shear Stress in the Natural History of Coronary Atherosclerosis and Vascular RemodelingJACC, 2007
- Non-Newtonian models for molecular viscosity and wall shear stress in a 3D reconstructed human left coronary arteryMedical Engineering & Physics, 2007
- Influence of wall elasticity in patient-specific hemodynamic simulationsComputers & Fluids, 2007
- Non-Newtonian blood flow in human right coronary arteries: Transient simulationsJournal of Biomechanics, 2006
- Hyperelastic modelling of arterial layers with distributed collagen fibre orientationsJournal of The Royal Society Interface, 2005
- Static and dynamic changes in carotid artery diameter in humans during and after strenuous exerciseThe Journal of Physiology, 2003
- Two-equation eddy-viscosity turbulence models for engineering applicationsAIAA Journal, 1994