A multiple closed‐loops robotic calibration for accurate surgical puncture
Authors:
- 16 February 2021
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 17 (3)
Abstract
Background: Robotic puncture system increasingly demands stringent standard in target location accuracy. The positional and orientational transformation relationships among all components of the system are supposed to be calibrated and identified preoperatively.Aims: The target location performance is directly determined by the calibration result. Therefore, a multiple closed‐loops calibration approach is proposed to achieve high‐level calibration accuracy in robotic puncture system.Materials & Methods: This method takes as input the three‐dimensional position information of the retro‐reflective markers mounted on the surgical tool, which is detected by the optical tracking system in real time during robotic movement. There is less complicated mathematical derivation and calculation in the presented algorithm by applying the closed‐loop principle.Results: Experimental results validate that it can achieve accurate robotic target location with less input data and computation‐cost, satisfying the clinical puncture requirements.Discussion: The spatial calibration between robotic arm and optical tracking system efficiently realised by the presented approach present an alternative which can be safely applied to the robotic puncture system for accurate insertion.Conclusion: Overall, a multiple closed‐loops calibration approach is proposed in this work, which may increase surgical efficiency.Keywords
Funding Information
- National Natural Science Foundation of China (U1301258)
This publication has 30 references indexed in Scilit:
- Calibration-Based Iterative Learning Control for Path Tracking of Industrial RobotsIEEE Transactions on Industrial Electronics, 2014
- Online Serial Manipulator Calibration Based on Multisensory Process Via Extended Kalman and Particle FiltersIEEE Transactions on Industrial Electronics, 2014
- Cone-beam Computed Tomography-guided Stereotactic Liver Punctures: A Phantom StudyCardioVascular and Interventional Radiology, 2013
- Design and In Vivo Evaluation of a Robotized Needle Insertion System for Small AnimalsIEEE Transactions on Biomedical Engineering, 2013
- Percutaneous radiofrequency ablation for hepatocellular carcinomaCancer, 2005
- A noise-tolerant algorithm for robotic hand-eye calibration with or without sensor orientation measurementIEEE Transactions on Systems, Man, and Cybernetics, 1993
- Tumor Size Determines the Efficacy of Percutaneous Ethanol Injection for the Treatment of Small Hepatocellular CarcinomaHepatology, 1992
- Use of CT and MR imaging to distinguish intracranial lesions and to define the need for biopsy in AIDS patientsJournal of Neurosurgery, 1990
- Closed-form solution of absolute orientation using unit quaternionsJournal of the Optical Society of America A, 1987
- Computed Medical ImagingScience, 1980