Photon Interaction Coefficients for the Colorectal Cancer Tissue
Authors:
- 1 October 2022
- journal article
- research article
- Published by Medknow in Journal of Medical Physics
- Vol. 47 (4) , 381-386
Abstract
Purpose: The application of radiotherapy to the treatment of cancer requires the knowledge of photon interaction coefficients such as mass attenuation (μm) and mass energy-absorption coefficients (μen/ρ). Although these coefficients have been determined for different tissues, it is lacking for the colorectal cancer (CRC) tissue in the literature. This study determines the μm and μen/ρ for the CRC tissue within the radiotherapy energy range. Materials and Methods: The CRC tissue from autopsy patients was freeze-dried, grounded into a fine powder, and made into pellets of 1 cm thickness. The elements detected in the CRC tissue using Rutherford backscattering spectrometry were used in XCOM to determine the theoretical values of μm and μen/ρ. The CRC tissue was again exposed to X-rays of energies of 6 and 15MV, respectively, to determine its experimental values of μm and μen/ρ. Results: Elements detected included carbon, oxygen and nitrogen making up 96.67%, high atomic number and trace elements making up the remaining 3.33% fraction of the CRC tissue. Conclusion: The theoretical and experimental μm and μen/ρ values showed a good agreement of about 2% difference between them. These values can be used to simulate the CRC tissue with respect to μm and μen/ρ.Keywords
This publication has 24 references indexed in Scilit:
- Comparative Trace Elemental Analysis in Cancerous and Noncancerous Human Tissues Using PIXEJournal of Biophysics, 2013
- Distribution of trace elements like calcium, copper, iron and zinc in serum samples of colon cancer – A case control studyJournal of King Saud University – Science, 2011
- Elemental fingerprinting of tumorous and adjacent non-tumorous tissues from patients with colorectal cancer using ICP-MS, ICP-OES and chemometric analysisBioMetals, 2009
- Parameters and computer software for the evaluation of mass attenuation and mass energy-absorption coefficients for body tissues and substitutesJournal of Medical Physics, 2007
- Measurement of attenuation coefficients for bone, muscle, fat and water at 140, 364 and 662keV -ray energiesJournal of Quantitative Spectroscopy and Radiative Transfer, 2006
- Colon tissue concentrations of copper, iron, selenium, and zinc in colorectal carcinoma patientsChemical Papers, 2006
- X-Ray Mass Attenuation Coefficient of Silicon: Theory versus ExperimentPhysical Review Letters, 2003
- Serum and tissue trace elements in colorectal cancerJournal of Surgical Oncology, 1993
- The composition of body tissuesBritish Journal of Radiology, 1986
- X-ray attenuation coefficients of elements and mixturesPhysics Reports, 1981