Effects of nonuniform acceptance in anisotropic flow measurements

Authors:
  • ISIlya Selyuzhenkov
    Ilya Selyuzhenkov
  • SVSergei Voloshin
    Sergei Voloshin

Abstract
Applicability of anisotropic flow measurement techniques and their extension for detectors with non-uniform azimuthal acceptance are discussed. Considering anisotropic flow measurement with two and three (mixed harmonic) azimuthal correlations we introduce a set of observables based on the x and y components of the event flow vector. These observables provide independent measures of anisotropic flow, and can be used to test self-consistency of the analysis. Based on these observables we propose a technique that explicitly takes into account the effects of non-uniform detector acceptance. Within this approach the acceptance corrections, as well as parameters which define the method applicability, can be determined directly from experimental data. For practical purposes a brief summary of the method is provided at the end.Comment: 7 pages, minor changes, discussion on the multiplicity correlations due to detector effects has been expande