Radiation impedance study of a capacitive micromachined ultrasonic transducer by finite element analysis
Author:
- 31 July 2015
- journal article
- research article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 138 (2) , 614-623
Abstract
In this study, radiation impedance of a capacitive micromachined ultrasonic transducer composed of square-shaped membranes arranged in m x m configuration (m = 1 - 5) is investigated using finite element analysis (FEA) of a commercially available software package (ANSYS). Radiation impedance is calculated for immersed membranes operating in conventional and collapse modes. Individual membrane response within the multi-membrane configuration is analyzed, and excited modes and their effects on radiation impedance and the pressure spectra are reported. This FEA provides an accurate behavior of the acoustic coupling of a thin membrane in a multi-membrane configuration, and extends above the anti-resonance frequency. The first resonance frequency of the membrane is excited for m x m (m >= 3) configuration in conventional mode and for m x m (m >= 2) configuration in collapse mode. Therefore, this frequency is determined to be responsible for the adverse effects observed in radiation impedance and pressure spectrum. A membrane configuration, which is missing the central membrane from the full m x m configuration is proposed, and is investigated with the FEA. This study is beneficial for the design of precise transducers suited for biomedical applications. (C) 2015 Acoustical Society of America.Keywords
This publication has 17 references indexed in Scilit:
- Radiation impedance of an array of circular capacitive micromachined ultrasonic transducers in collapsed state2012
- Capacitive micromachined ultrasonic transducers for medical imaging and therapyJournal of Micromechanics and Microengineering, 2011
- A multiscale model for array of capacitive micromachined ultrasonic transducersThe Journal of the Acoustical Society of America, 2010
- Radiation impedance of an array of circular capacitive micromachined ultrasonic transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2010
- A lumped-circuit model for the radiation impedance of a circular piston in a rigid baffleIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2008
- Acoustic coupling in capacitive microfabricated ultrasonic transducers: modeling and experimentsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005
- Dynamic analysis of capacitive micromachined ultrasonic transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005
- Dynamic FEM analysis of multiple cmut cells in immersion2005
- Capacitive micromachined ultrasonic transducer design for high power transmissionIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005
- Dynamic analysis of CMUTs in different regimes of operation2004