Longitudinal Zeolite-Iron Oxide Nanocomposite Deposited Capacitance Biosensor for Interleukin-3 in Sepsis Detection
Open Access
- 26 April 2021
- journal article
- research article
- Published by Springer Nature in Discover Nano
- Vol. 16 (1) , 1-10
Abstract
Sepsis is an extreme condition involving a physical response to severe microbial infection and causes fatal and life-threatening issues. Sepsis generates during the chemicals release with the immune system into the bloodstream for fighting against an infection, which causes the inflammation and leads to the medical emergency. A complexed longitudinal zeolite and iron oxide nanocomposite was extracted from coal mine fly ash and utilized to improve the surface characteristics of the capacitance biosensor to identify sepsis attacks. Anti-interleukin-3 (anti-IL-3) antibody was attached to the zeolite- and iron oxide-complexed capacitance electrode surface through an amine linker to interact with the sepsis biomarker IL-3. The morphological and chemical components of the nanocomplex were investigated by FESEM, FETEM, and EDX analyses. At approximately 30 nm, the longitudinal zeolite and iron oxide nanocomposite aided in attaining the limit of IL-3 detection of 3 pg/mL on the linear curve, with a regression coefficient (R2) of 0.9673 [y = 1.638x − 1.1847]. A lower detection limit was achieved in the dose-dependent range (3–100 pg/mL) due to the higher amount of antibody immobilization on the sensing surface due to the nanomaterials and the improved surface current. Furthermore, control experiments with relevant biomolecules did not show capacitance changes, and spiked IL-3 in human serum increased capacitance, indicating the specific and selective detection of IL-3. This study identifies and quantifies IL-3 via potentially useful methods and helps in diagnosing sepsis attack.Keywords
This publication has 43 references indexed in Scilit:
- Label free redox capacitive biosensingBiosensors and Bioelectronics, 2013
- A high-performance waveguide-mode biosensor for detection of factor IX using PEG-based blocking agents to suppress non-specific binding and improve sensitivityThe Analyst, 2013
- Construction of a densely poly(ethylene glycol)-chain-tethered surface and its performancePolymer Journal, 2011
- Conductometric enzyme biosensors based on natural zeolite clinoptilolite for urea determinationMaterials Science and Engineering: C, 2011
- A novel urea conductometric biosensor based on zeolite immobilized ureaseTalanta, 2011
- Biosensing applications of surface plasmon resonance-based Biacore technologySensors and Actuators B: Chemical, 2010
- Highly specific detection of interleukin-6 (IL-6) protein using combination tapered fiber-optic biosensor dip-probeBiosensors and Bioelectronics, 2009
- Electroanalytical Applications of Microporous Zeolites and Mesoporous (Organo)Silicas: Recent TrendsElectroanalysis, 2008
- Enhanced immunoresponse of antibody/mixed-PEG co-immobilized surface construction of high-performance immunomagnetic ELISA systemJournal of Colloid and Interface Science, 2007
- Decrease of serum levels of the anti-inflammatory cytokine interleukin-10 in patients with advanced chronic heart failureClinical Science, 2003