Higher blood glucose and larger fluctuations detected postoperatively using continuous glucose monitoring: a preliminary study following total knee or hip arthroplasty
Authors:
Open Access
- 1 January 2019
- journal article
- research article
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 6 (1) , 15
Abstract
S: Background: The control of diabetes mellitus (DM) should help reduce the incidence of periprosthetic joint infection (PJI). Self‐monitoring of blood glucose (SMBG) concentration is usually undertaken at fixed time‐points. Therefore, the extent of postoperative blood glucose fluctuation might be underestimated. To provide a more comprehensive assessment, continuous glucose monitoring (CGM) is beginning to be used. However, no previous studies have evaluated blood glucose concentrations using CGM following orthopedic surgery. Therefore, the differences between the maximum blood glucose concentrations measured using SMBG and CGM, and the mean amplitude of the glycemic fluctuation in patients with frank diabetes mellitus (DM) or pre‐diabetes were evaluated.Blood glucose was measured in 20 patients who had undergone total hip or total knee arthroplasty (12 patients with DM and eight with pre‐diabetes). Patients were fitted with a CGM device in the operating room, which was worn for 6 days postoperatively, and used to evaluate blood glucose concentration continuously. SMBG was performed simultaneously for the same period.Results: The mean difference between the maximum blood glucose concentrations measured using SMBG and CGM was 25.0 ± 20.3 mg/dl (range, − 17 to 81 mg/dl), with the concentrations measured using CGM tending to be higher than those measured using SMBG (P = 0.04). Blood glucose concentrations measured using CGM tended to be higher than those measured using SMBG until postoperative day 2, and to decrease gradually after postoperative day 4. There were no significant differences in the standard deviation of the blood glucose concentrations between the two groups.Conclusions: Blood glucose concentrations > 200 mg/dl and larger fluctuations were more frequently recorded using CGM than SMBG, especially until postoperative day 2. Thus, CGM is more useful for the identification of high blood glucose concentrations and larger fluctuations. However, this information was not provided in real time.Keywords
This publication has 22 references indexed in Scilit:
- Accuracy of 2 Different Continuous Glucose Monitoring Systems in Patients Undergoing Cardiac SurgeryJournal of Diabetes Science and Technology, 2016
- Patient-Related Risk Factors for Periprosthetic Joint Infection after Total Joint Arthroplasty: A Systematic Review and Meta-AnalysisPLOS ONE, 2016
- Do Glycemic Markers Predict Occurrence of Complications After Total Knee Arthroplasty in Patients With Diabetes?Clinical Orthopaedics and Related Research, 2014
- Insulin treatment guided by subcutaneous continuous glucose monitoring compared to frequent point-of-care measurement in critically ill patients: a randomized controlled trialCritical Care, 2014
- Treatment Recommendations Following 3-Day Masked Continuous Glucose Monitoring (CGM) in Youth With Type 1 DiabetesJournal of Diabetes Science and Technology, 2014
- Abnormal Glycemic Profiles by CGMS in Obese First-Degree Relatives of Type 2 Diabetes Mellitus PatientsDiabetes Technology & Therapeutics, 2013
- Elevated Postoperative Blood Glucose and Preoperative Hemoglobin A1C Are Associated with Increased Wound Complications Following Total Joint ArthroplastyJournal of Bone and Joint Surgery, 2013
- Prognostic value of early in-hospital glycemic excursion in elderly patients with acute myocardial infarctionCardiovascular Diabetology, 2013
- Obesity, Diabetes, and Preoperative Hyperglycemia as Predictors of Periprosthetic Joint InfectionJournal of Bone and Joint Surgery, 2012
- Does HbA1c represent a valid index for tight control of glucose in type 1 diabetes?Diabetes Research and Clinical Practice, 2008