The HemoScreen, a novel haematology analyser for the point of care
Authors:
- 19 January 2016
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 69 (8) , 720-725
Abstract
Background and aims A haematology analyser, based on a new technology, is presented herein. The analyser that provides a complete blood count (CBC) and five-part differential accepts disposable cartridges containing all required reagents, making it maintenance-free and ideal for point-of-care (POC) settings. The test reproducibility and imperviousness to analytical errors are attributed to the imaging-based analysis employed. Imaging enables cell-morphology-based differentiation, which is analogous to the gold standard microscopic analysis. This article presents the HemoScreen new technology and evaluates its performance through a small-scale study conducted in its designated clinical settings. Methods Thirty anticoagulated whole blood samples were analysed on the HemoScreen and Sysmex XE-2100. Linear regression was performed for the methods comparison. Two samples with 15 replicates were processed for imprecision. Ease of use of the device was also considered. Results The HemoScreen demonstrated acceptable imprecision and good agreement with the Sysmex XE-2100. The white blood cells (WBCs), red blood cells (RBCs), haemoglobin (HGB), haematocrit (HCT), platelets (PLT), neutrophils, lymphocytes and eosinophils have coefficients of correlation (r) >0.97. For mean cell volume (MCV), mean cell HGB (MCH) and RBC distribution width (RDW), r values ranged from 0.92 to 0.96. For mean cell HGB concentration (MCHC) and monocytes r=0.82 was demonstrated. User-friendliness and suitability of the device for operation in the designated POC settings was also confirmed. Conclusions The HemoScreen employs innovative technologies of viscoelastic focusing and microfluidics within a disposable cartridge for an image-based blood cell analysis. By providing accurate and repeatable CBC and five-part differential results within minutes and maintaining the simplicity of operation, the HemoScreen could have far-reaching implications for use at POC. Further extended evaluation is in progress.Keywords
This publication has 17 references indexed in Scilit:
- Digital Image Analysis of Blood CellsClinics In Laboratory Medicine, 2015
- Particle alignment in a viscoelastic liquid flowing in a square-shaped microchannelLab on a Chip, 2013
- Effective estimation of correct platelet counts in pseudothrombocytopenia using an alternative anticoagulant based on magnesium saltBritish Journal of Haematology, 2013
- Evaluation of the QBC Star centrifugal three-part differential haematology systemBritish Journal of Biomedical Science, 2013
- Single line particle focusing induced by viscoelasticity of the suspending liquid: theory, experiments and simulations to design a micropipe flow-focuserLab on a Chip, 2012
- Automated Blood Cell CountsAmerican Journal of Clinical Pathology, 2008
- Tunable Nonlinear Viscoelastic “Focusing” in a Microfluidic DevicePhysical Review Letters, 2007
- Performance Evaluation of the CellaVision DM96 SystemAmerican Journal of Clinical Pathology, 2005
- Quality specification in haematology: the automated blood cell countClinica Chimica Acta, 2004
- Practical Flow Cytometry2003