Minimal Preconditioning Effects Observed for Inflation Tests of Planar Tissues
Authors:
- Theresa K. TongeTTTheresa K. Tonge
- Barbara J. MurienneBMBarbara J. Murienne
- William RothkopfWRWilliam Rothkopf
- Thao D. NguyenTNThao D. Nguyen
- 23 September 2013
- journal article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 135 (11) , 114502-11450214
Abstract
The purpose of this study is to investigate the effects of preconditioning on the deformation response of planar tissues measured by inflation tests. The inflation response of test specimens, including the bovine cornea, bovine and porcine sclera, and human skin, exhibited a negligible evolving deformation response when subjected to repeated pressure loading with recovery periods between cycles. Tissues obtained complete recovery to the reference state, and strain contours across the entire specimen were nearly identical at the maximum pressure of each load cycle. This repeatability was obtained regardless of strain history. These results suggest that negligible permanent change was induced in the microstructure by inflation testing. Additionally, we present data illustrating that a lack of a recovery period can result in an evolving deformation response to repeated loading that is commonly attributed to preconditioning. These results suggest that the commonly observed effects of preconditioning may be avoided by experimental design for planar tissues characterized by long collagen fibers arranged in the plane of the tissue. Specifically, if the test is designed to fully fix the specimen boundary during loading, adequate recovery periods are allowed after each load cycle, and loads are limited to avoid damage, preconditioning effects may be avoided for planar tissues.Keywords
This publication has 39 references indexed in Scilit:
- Biomechanics of the Human Posterior Sclera: Age- and Glaucoma-Related Changes Measured Using Inflation TestingInvestigative Ophthalmology & Visual Science, 2012
- Scleral mechanics: Comparing whole globe inflation and uniaxial testingExperimental Eye Research, 2011
- Stereoscopically Observed Deformations of a Compliant Abdominal Aortic Aneurysm ModelJournal of Biomechanical Engineering, 2011
- Preconditioning is Correlated With Altered Collagen Fiber Alignment in LigamentJournal of Biomechanical Engineering, 2011
- Deformation Measurements and Material Property Estimation of Mouse Carotid Artery Using a Microstructure-Based Constitutive ModelJournal of Biomechanical Engineering, 2010
- The inflation response of the posterior bovine scleraActa Biomaterialia, 2010
- High-Throughput Measurements of Hydrogel Tissue Construct MechanicsTissue Engineering Part C: Methods, 2009
- Viscoelasticity and Preconditioning of Rat Skin Under Uniaxial Stretch: Microstructural Constitutive CharacterizationJournal of Biomechanical Engineering, 2009
- Strain field measurements on mouse carotid arteries using microscopic three‐dimensional digital image correlationJournal of Biomedical Materials Research Part A, 2007
- Effects of Storage Time on the Mechanical Properties of Rabbit Peripapillary Sclera After EnucleationCurrent Eye Research, 2007