Improvement of power quality using variable leaky least mean square controller with adaptive shunt active filter for non linear loads
- 1 January 2023
- conference paper
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2857 (1)
Abstract
Power quality pose a major problem in the power system, and it is increasing particularly in the nonlinear devices. Usage of power electronic converters and inverters in nonlinear devices, source current possess an increase in the harmonic content. Due to increase in the harmonics, there are many drawbacks like power losses, power instability, and poor voltage and current waveforms. To provide reactive power compensation and reducing the problems of harmonic content pose an advantage in power systems. Hence, usage of filters will possess system stability. Many filters were used in the design system, in which passive filters are limited to use in compensation. Hence, active filters are used to compensate the system. In this paper, an Adaptive Shunt Active Filter is used with Variable Leaky Least Mean Square (VLLMS) controller is used. The proposed methodology is used to reduce the harmonic content, improves the power quality, reduce the power losses and improves the power factor in a nonlinear load. PI controller is used to regulate the DC Capacitor voltage. The proposed design is implemented and validated using MATLAB SIMULINK.Keywords
This publication has 14 references indexed in Scilit:
- Nearly constant switching frequency hysteresis controller for VSI fed IM drives based on Current Error Space Vector2016
- Parameter-Insensitive Mixed-Signal Hysteresis-Band Current Control for Point-of-Load Converters With Fixed Frequency and Robust StabilityIEEE Transactions on Power Electronics, 2016
- Voltage Vector Error Fault Diagnosis for Open-Circuit Faults of Three-Phase Four-Wire Active Power FiltersIEEE Transactions on Power Electronics, 2016
- Harmonic current and voltage compensation using HSAPF based on hybrid control approach for synchronous reference frame methodInternational Journal of Electrical Power & Energy Systems, 2016
- Back-Propagation Control Algorithm for Power Quality Improvement Using DSTATCOMIEEE Transactions on Industrial Electronics, 2013
- A Noniterative Optimized Algorithm for Shunt Active Power Filter Under Distorted and Unbalanced Supply VoltagesIEEE Transactions on Industrial Electronics, 2012
- Modified PQ control for power quality improvement of standalone hybrid wind diesel battery system2012
- Feedback-Feedforward PI-Type Iterative Learning Control Strategy for Hybrid Active Power Filter With Injection CircuitIEEE Transactions on Industrial Electronics, 2010
- Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A SurveyIEEE Transactions on Industrial Electronics, 2006
- Active power filter for nonlinear AC loadsIEEE Transactions on Power Electronics, 1994