First in-human results of the MAGiC robotic magnetic navigation radiofrequency ablation catheter
Authors:
- Gediminas RackauskasGRGediminas Rackauskas
- Ricardas KundelisRKRicardas Kundelis
- Jurate BarysieneJBJurate Barysiene
- Diana SudavicieneDSDiana Sudaviciene
- Justinas BaceviciusJBJustinas Bacevicius
- Monika KezeviciuteMKMonika Kezeviciute
- Germanas MarinskisGMGermanas Marinskis
- Niels Christian Foldager SandgaardNSNiels Christian Foldager Sandgaard
- Christian JønsCJChristian Jøns
- Peter Karl JacobsenPJPeter Karl Jacobsen
Open Access
- 25 June 2025
- journal article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 69 (7) , 1687-1693
Abstract
Robotic magnetic navigation (RMN) has demonstrated clinical utility in treating arrhythmia patients by providing direct distal-tip control of an ablation catheter, enhancing catheter precision, safety, and stability with an atraumatic catheter design. We aimed to assess the first in-human efficacy and safety of the new RMN-guided MAGiCTM radiofrequency ablation catheter. This prospective, multicenter single-arm, unblinded study enrolled 67 patients with arrhythmias that met EHRA guidelines for catheter ablation. All patients were treated for their index arrhythmia with the MAGiC RMN catheter. All other devices used in the procedures were approved for treatment including a RMN System (Genesis/Niobe®) used to navigate the MAGiC catheter. Acute procedural success and adverse events were assessed for all patients through discharge from the hospital in the days following the procedure. Sixty-seven patients were treated as follows: 25 cases of atrioventricular nodal reentrant tachycardia, 19 of premature ventricular contractions, 8 of Wolf-Parkinson-White (WPW) syndrome, 8 of atrial fibrillation, 3 of atrial flutter, and 4 of ventricular tachycardia. Acute procedural success was 94%. There was one cardiac tamponade due to perforation of the right ventricular outflow tract during ablation. Otherwise, no adverse events were observed. The results of this study demonstrate good acute efficacy and safety of the MAGiC RMN ablation catheter independent of underlying arrhythmias. Contact force and stability with MAGiC seem improved compared to previous catheters available with RMN, and therefore radiofrequency energy delivery needs careful attention, especially in thin areas of the myocardium. Additional long-term data are needed.Keywords
Funding Information
- Stereotaxis (Speakers fee)
- Stereotaxis (Study financial support)
This publication has 12 references indexed in Scilit:
- The impedance drop early after energy delivery predicts steam pops during radiofrequency ablationEuropean Heart Journal, 2024
- Best practices in robotic magnetic navigation-guided catheter ablation of cardiac arrhythmias, a position paper of the Society for Cardiac Robotic NavigationFrontiers in Cardiovascular Medicine, 2024
- 2024 ESC Guidelines for the management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)European Heart Journal, 2024
- 2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillationEP Europace, 2024
- Management of patients with an electrical storm or clustered ventricular arrhythmias: a clinical consensus statement of the European Heart Rhythm Association of the ESC—endorsed by the Asia-Pacific Heart Rhythm Society, Heart Rhythm Society, and Latin-American Heart Rhythm SocietyEP Europace, 2024
- 2019 ESC Guidelines for the management of patients with supraventricular tachycardiaThe Task Force for the management of patients with supraventricular tachycardia of the European Society of Cardiology (ESC)European Heart Journal, 2019
- Ablation Outcomes and Predictors of Mortality Following Catheter Ablation for Ventricular Tachycardia: Data From the German Multicenter Ablation RegistryJournal of the American Heart Association, 2018
- Long-term symptom improvement and patient satisfaction following catheter ablation of supraventricular tachycardia: insights from the German ablation registryEuropean Heart Journal, 2017
- Safety and efficacy in ablation of premature ventricular contraction: data from the German ablation registryClinical Research in Cardiology, 2016
- Steam pops during irrigated radiofrequency ablation: Feasibility of impedance monitoring for preventionHeart Rhythm, 2008