Numerical Study of Purely Viscous Non-Newtonian Flow in an Abdominal Aortic Aneurysm
Authors:
- 6 August 2014
- journal article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 136 (10) , 101001
Abstract
It is well known that blood has non-Newtonian properties, but it is generally accepted that blood behaves as a Newtonian fluid at shear rates above 100 s−1. However, in transient conditions, there are times and locations where the shear rate is well below 100 s−1, and it is reasonable to infer that non-Newtonian effects could become important. In this study, purely viscous non-Newtonian (generalized Newtonian) properties of blood are incorporated into the simulation-based framework for cardiovascular surgery planning developed by Taylor et al. (1999, “Predictive Medicine: Computational Techniques in Therapeutic Decision Making,” Comput. Aided Surg., 4, pp. 231–247; 1998, “Finite Element Modeling of Blood Flow in Arteries,” Comput. Methods Appl. Mech. Eng., 158, pp. 155–196). Equations describing blood flow are solved in a patient-based abdominal aortic aneurysm model under steady and physiological flow conditions. Direct numerical simulation (DNS) is used, and the complex flow is found to be constantly transitioning between laminar and turbulent in both the spatial and temporal sense. It is found for the case simulated that using the non-Newtonian viscosity modifies the solution in subtle ways that yield a mesh-independent solution with fewer degrees of freedom than the Newtonian counterpart. It appears that in regions of separated flow, the lower shear rate produces higher viscosity with the non-Newtonian model, which reduces the associated resolution needs. When considering the real case of pulsatile flow, high shear layers lead to greater unsteadiness in the Newtonian case relative to the non-Newtonian case. This, in turn, results in a tendency for the non-Newtonian model to need fewer computational resources even though it has to perform additional calculations for the viscosity. It is also shown that both viscosity models predict comparable wall shear stress distribution. This work suggests that the use of a non-Newtonian viscosity models may be attractive to solve cardiovascular flows since it can provide simulation results that are presumably physically more realistic with at least comparable computational effort for a given level of accuracy.Keywords
This publication has 41 references indexed in Scilit:
- Quantification of Hemodynamics in Abdominal Aortic Aneurysms During Rest and Exercise Using Magnetic Resonance Imaging and Computational Fluid DynamicsAnnals of Biomedical Engineering, 2010
- Cardiovascular flow simulation at extreme scaleComputational Mechanics, 2009
- Vascular fluid dynamics and vascular biology and diseaseMathematical Methods in the Applied Sciences, 2001
- The influence of the non-Newtonian properties of blood on the flow in large arteries: unsteady flow in a 90° curved tubeJournal of Biomechanics, 1999
- Predictive Medicine: Computational Techniques in Therapeutic Decision-MakingComputer Aided Surgery, 1999
- Pulsatile Velocity Measurements in a Model of the Human Abdominal Aorta Under Resting ConditionsJournal of Biomechanical Engineering, 1994
- Steady Flow in Abdominal Aortic Aneurysm ModelsJournal of Biomechanical Engineering, 1993
- Vascular Fluid Mechanics, the Arterial Wall, and AtherosclerosisJournal of Biomechanical Engineering, 1992
- On the Application of a Constitutive Equation for Whole Human BloodJournal of Biomechanical Engineering, 1990
- Numerical flow studies in human carotid artery bifurcations: basic discussion of the geometric factor in atherogenesisJournal of Biomedical Engineering, 1990