Picogram Measurement of Volatile n-Alkanes (n-Hexane through n-Dodecane) in Blood Using Solid-Phase Microextraction To Assess Nonoccupational Petroleum-Based Fuel Exposure
- 16 May 2008
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (12) , 4666-4674
Abstract
We describe here a new method for the analysis of alkanes (n-hexane, n-heptane, n-octane, n-nonane, n-decane, n-undecane, and n-dodecane) in blood using headspace solid-phase microextraction gas chromatography/mass spectrometry. This method is used to measure picogram per milliliter levels of n-alkanes in blood that may result from nonoccupational exposure to alkanes and other volatile nonpolar compounds from common sources such as petroleum-based fuel. This alkane signature is useful in distinguishing typical fuel biomarkers (e.g., benzene and toluene) from other confounding exposure sources such as cigarette smoke. Development of this method required special attention to sample handling as alkanes are not highly soluble in aqueous matrixes and exist as ubiquitous compounds found in many laboratory materials and the environment. In particular, significant n-hexane contamination (∼0.4 ng/mL) occurred from collecting blood samples in vacutainers. This residue was removed by boiling the vacutainer stoppers in methanol followed by vacuum baking. For all the alkanes, the calculated accuracy demonstrated for the water-based standards ranged from 3.3% to 17% as deduced from the difference of the lowest and middle standards from the curve fit. Quality control data among runs over a 10 month period were found to vary from 14% to −29%, with a few exceptions. The resulting quantification limits for n-hexane through n-decane ranged from 0.069 to 0.132 ng/mL. In the analysis of 1200 blood samples from people with no known occupational exposure, median blood levels for all n-alkanes were below these quantification limits. n-Hexane levels above the method detection limit were, however, found in 1.3% of the samples.Keywords
This publication has 25 references indexed in Scilit:
- An Improved Approach for Accurate Quantitation of Benzene, Toluene, Ethylbenzene, Xylene, and Styrene in BloodAnalytical Chemistry, 2006
- A review of analytical methods for the identification and quantification of hydrocarbons found in jet propellant 8 and related petroleum based fuelsBiomedical Chromatography, 2006
- Quantification of 31 volatile organic compounds in whole blood using solid-phase microextraction and gas chromatography–mass spectrometry☆Journal of Chromatography B, 2006
- Dose‐dependent production of urinary naphthols among workers exposed to jet fuel (JP‐8)American Journal of Industrial Medicine, 2004
- Comparison of unchanged n -hexane in alveolar air and 2,5-hexanedione in urine for the biological monitoring of n -hexane exposure in human volunteersInternational Archives of Occupational and Environmental Health, 2004
- A review of the USEPA's single breath canister (SBC) method for exhaled volatile organic biomarkersBiomarkers, 2002
- Solvents in urine as exposure markers.Toxicology Letters, 1999
- Potential health effects of gasoline and its constituents: A review of current literature (1990-1997) on toxicological data.Environmental Health Perspectives, 1998
- Determination of benzene and associated volatile compounds in mainstream cigarette smokeThe Analyst, 1998
- Carcinogenicity of Gasoline: A Review of Epidemiological EvidenceAnnals of the New York Academy of Sciences, 1997