Effects of an Over-the-Counter Vented Mouthguard on Cardiorespiratory Responses to Exercise and Physical Agility
Authors:
- Stephen P. BaileySBStephen P. Bailey
- Thomas J. WillauerTWThomas J. Willauer
- Gytis BalilionisGBGytis Balilionis
- Laura E. WilsonLWLaura E. Wilson
- John T. SalleyJSJohn T. Salley
- Elizabeth K. BaileyEBElizabeth K. Bailey
- Tony L. StricklandTSTony L. Strickland
- 1 March 2015
- journal article
- Published by Wolters Kluwer Health in Journal of Strength & Conditioning Research
- Vol. 29 (3) , 678-684
Abstract
They believe that they impair their ability to breath and negatively affect performance. Recently, some manufacturers have developed “vented” mouthguards (VentMGs) to address this concern. The purposes of this investigation were to describe the impact of a commercially available “vented” boil-and-bite mouthguard on the physiological responses to graded exercise and to determine whether the use of the same mouthguard influences performance during traditional physical agility tests. Recreationally trained males (n = 15) (age = 24 ± 1 year; JOURNAL/jscr/04.03/00124278-201503000-00014/math_14MM1/v/2021-02-09T094113Z/r/image-tiff = 43.5 ± 1.9 ml·kg−1·min−1; body mass index = 25.2 ± 0.9) completed 3 randomly assigned trials where they wore no mouthguard (control), a traditional mouthguard (TradMG), or a VentMG. During each trial, subjects completed a modified maximal exercise test on a cycle ergometer and a series of physical agility tests (40-m dash, vertical leap, broad jump, 3-cone drill, and shuttle run). No differences were seen between control and the TradMG in any cardiorespiratory measures at any time during the maximal exercise test. Ventilation and blood lactate were lower (p ≤ 0.05) during VentMG at 200 W and at MAX; however, no differences in JOURNAL/jscr/04.03/00124278-201503000-00014/math_14MM2/v/2021-02-09T094113Z/r/image-tiff were observed. Although TradMG had no impact on physical agility, VentMG produced a higher (1.9 cm; p = 0.03) vertical leap than control. Both mouthguard conditions negatively affected perceptions of breathability, comfort, and ability to communicate, but no differences existed between the 2 conditions. These findings confirm that TradMG has no negative impact on physiological function during exercise and physical agility; however, VentMG may have a positive impact at higher workload and on vertical leap....Keywords
This publication has 17 references indexed in Scilit:
- A method-comparison study regarding the validity and reliability of the Lactate Plus analyzerBMJ Open, 2013
- The Effects of a Customized Over-the-Counter Mouth Guard on Neuromuscular Force and Power Production in Trained Men and WomenJournal of Strength & Conditioning Research, 2012
- Utilization of Modified NFL Combine Testing to Identify Functional Deficits in Athletes Following ACL ReconstructionJournal of Orthopaedic & Sports Physical Therapy, 2011
- The Effect of Mouthguard Design on Respiratory Function in AthletesClinical Journal of Sport Medicine, 2011
- Effects of a neuromuscular dentistry-designed mouthguard on muscular endurance and anaerobic powerComparative Exercise Physiology, 2010
- Influence of custom‐made mouth guards on strength, speed and anaerobic performance of taekwondo athletesDental Traumatology, 2009
- Jaw Clenching Results in Concurrent Activation Potentiation During the Countermovement JumpJournal of Strength & Conditioning Research, 2008
- Effectiveness of mouthguards in reducing neurocognitive deficits following sports‐related cerebral concussionDental Traumatology, 2006
- Influence of Maxillary Mouthguards on Physiological ParametersMedicine & Science in Sports & Exercise, 2006
- Physiological effects of wearing mouthguards.British Journal of Sports Medicine, 1991