Evaluation of intra- and interobserver reliability and image reproducibility to assess usefulness of high-resolution ultrasonography for measurement of anterior segment structures of canine eyes
Authors:
- Paul E. MillerPMPaul E. Miller
- Kathryn A. DiehlKDKathryn A. Diehl
- 1 October 2005
- journal article
- research article
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 66 (10) , 1775-1779
Abstract
Objective —To evaluate the usefulness of high-resolution ultrasonography (HRUS) for measurements of anterior segment structures in canine eyes. Animals —4 clinically normal Beagles. Procedure —Images were obtained from 8 eyes with a handheld 20-MHz transducer. Eleven anterior segment structures on each image were measured 5 times by 2 independent observers. Coefficients of variation (CVs) for measurements were used to assess intraobserver reliability. Interobserver reliability was assessed by comparing measurements obtained by the 2 observers from the same images. Five images were sequentially obtained from 2 locations (ie, superior and temporal) to evaluate image reproducibility. Anterior segment structures were measured once on each image; image reproducibility was assessed by use of the CV for each parameter measured. Imaging location was assessed by comparison of CV for measurements from each location. Results —CVs were < 10% for observer A for all measurements except the ciliary cleft area (11.63%). The CVs were > 10% for observer B for measurements of the angle recess area (18.51%) and ciliary cleft width (17.44%) and area (16.01%). Significant differences in measurements between observers were found for 5 of 11 anterior segment structures. Imaging the superior aspect of the globe provided the most reproducible images, although image reproducibility was still somewhat variable, with the highest and lowest CVs for measurements of 33.01% and 11.32%, respectively, in the superior position. Conclusions and Clinical Relevance —High-resolution ultrasound images can be used to reliably measure various anterior segment structures. Clinically relevant findings in the anterior segment of canine eyes may be detectable by use of HRUS. ( Am J Vet Res 2005;66:1775–1779)Keywords
This publication has 10 references indexed in Scilit:
- Anterior segment imaging: ultrasound biomicroscopyOphthalmology Clinics of North America, 2004
- Use of high-resolution ultrasound as a diagnostic tool in veterinary ophthalmologyJournal of the American Veterinary Medical Association, 2003
- Intraobserver and interobserver reliability of the R/D score for evaluation of iris configuration by ultrasound biomicroscopy, in patients with pigment dispersion syndromeEye, 2002
- Quantitative assessment of the anterior segment using ultrasound biomicroscopyCurrent Opinion in Ophthalmology, 2000
- Advances in ultrasound biomicroscopyUltrasound in Medicine & Biology, 2000
- Ultrasound biomicroscopy. III. Accuracy and agreement of measurementsActa Ophthalmologica Scandinavica, 1999
- ULTRASOUND BIOMICROSCOPYRadiologic Clinics of North America, 1998
- Ultrasound biomicroscopy. II. Intraobserver and interobserver reproducibility of measurementsActa Ophthalmologica Scandinavica, 1998
- Comparison of gonioscopy and ultrasound biomicroscopy for evaluating the iridocorneal angle in dogsJournal of the American Veterinary Medical Association, 1998
- Ultrasound biomicroscopy. I. Precision of measurementsActa Ophthalmologica Scandinavica, 1998