Thrombus-related focal in-stent restenosis after everolimus-eluting stent implantation
Authors:
- 18 April 2013
- journal article
- case report
- Published by Springer Nature in Heart and Vessels
- Vol. 29 (2) , 273-277
Abstract
A 60-year-old man who had received repeated angioplasty for silent ischemia was suspected to have restenosis based on radioisotope imaging (exercise-RI) findings 6 months after everolimus-eluting stent (EES) implantation (3.5 × 28, 3.5 × 28, 3.0 × 18 mm). The stents had been implanted for chronic total occlusion of the right coronary artery (RCA), and the patient was on continuous dual antiplatelet therapy. Diagnostic angiography demonstrated in-stent restenosis in the proximal RCA, which was treated by optical coherence tomography (OCT)-guided cutting balloon angioplasty with distal protection. OCT findings of the stenotic segment before angioplasty showed that the lesion had complex features. The lesion was successfully dilated, and whitish material obtained by a distal protection device was composed of fibrin thrombi with neutrophils and small pieces of mature fibrocellular neointima. The mechanisms and patterns of restenosis after EES placement have not been well clarified. This case may reflect a restenosis pattern (i.e., asymptomatic, focal, and thrombi-related) in the era of the newer generation of drug-eluting stents.Keywords
This publication has 13 references indexed in Scilit:
- OCT-Verified Neointimal Hyperplasia Is Increased at Fracture Site in Drug-Eluting StentsJACC: Cardiovascular Imaging, 2012
- Disruption of Atherosclerotic Neointima Seven Years After Bare Metal Stent DeploymentInternational Heart Journal, 2012
- Optical Coherence Tomographic Analysis of In-Stent Neoatherosclerosis After Drug–Eluting Stent ImplantationCirculation, 2011
- Diffuse in-stent restenosis of CYPHER® stent due to hypersensitivity reaction confirmed by pathohistological findingsHeart and Vessels, 2011
- Ruptured-plaque-like appearance of restenotic tissue following sirolimus-eluting stent implantation: an optical coherence tomography case study.2011
- The Pathology of Neoatherosclerosis in Human Coronary ImplantsJACC, 2011
- Intravascular ultrasound, angioscopic and histopathological characterisation of heterogeneous patterns of restenosis after sirolimus-eluting stent implantation: insights into potential “thromborestenosis” phenomenonEuroIntervention, 2010
- One Step Forward and Two Steps Back With Drug-Eluting-StentsJACC: Cardiovascular Imaging, 2009
- Clinical End Points in Coronary Stent TrialsCirculation, 2007
- Long-Term Clinical and Angiographic Follow-Up After Coronary Stent Placement in Native Coronary ArteriesCirculation, 2002