Time-of-Flight Mass Spectrometry with a Pulsed Glow Discharge Ionization Source
Authors:
- 1 May 1997
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 69 (9) , 1715-1721
Abstract
The pulsed glow discharge (GD) plasma source exhibits several characteristics that make it ideally suited for use with time-of-flight mass spectrometry (TOFMS). TOFMS uniquely affords the ability to monitor a narrow temporal window for a time-varying process such as ion formation in the pulsed glow discharge plasma. Pulsed GD-TOFMS exhibited distinct advantages for the direct determination of trace elements in solid state samples. Initially, the pulse-powered GD-TOFMS system used for these investigations exhibited poor resolution. In an effort to improve resolution, a slit was introduced to narrow the ion beam orthogonally entering the extraction region of the TOFMS. In an effort to determine optimal operating conditions, the influence of slit width on TOF performance was investigated. In the course of this study, the slit width was found to influence isotope ratio accuracy as well as resolution. A slit width of 1.0 mm was determined to provide the best compromise between resolution and isotope ratio accuracy. Pulsed GD-TOFMS affords improved sensitivity and selectivity because Penning ionization is enhanced during the time period immediately following the termination of the discharge power. Ions sampled by an extraction pulse applied after power termination also yield a mass spectrum that is free of contributions arising from electron-ionized interferences. This advantage arises because only ions generated via the Penning ionization mechanism persist after the termination of discharge power. Sampling in the “afterpeak” time regime eliminates the saturation of the detector arising from discharge support gas ion signal.Keywords
This publication has 35 references indexed in Scilit:
- High mass resolution glow discharge mass spectrometry using an external ion source FT-ICR mass spectrometerAnalytical Chemistry, 1993
- Design and characterization of a radio-frequency-powered glow discharge source for double-focusing mass spectrometersAnalytical Chemistry, 1993
- Anomalous surface area change at an ultramicroelectrode during the reduction of molybdenum oxide powder in the absence of a solution phaseAnalytical Chemistry, 1991
- Design and performance of a matrix-assisted laser desorption time-of-flight mass spectrometer utilizing a pulsed nitrogen laserAnalytica Chimica Acta, 1991
- A plasma source for Fourier transform mass spectrometryPlasma Chemistry and Plasma Processing, 1989
- Collision-induced dissociation of polyatomic ions in glow discharge mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1989
- Laser desorption time-of-flight mass spectrometry using a 300-ps ultraviolet laserAnalytical Chemistry, 1988
- Glow discharge mass spectrometry: a current assessmentJournal of Analytical Atomic Spectrometry, 1988
- Glow discharge mass spectrometry-a powerful technique for the elemental analysis of solidsMicrochimica Acta, 1987
- Glow discharge mass spectrometryAnalytical Chemistry, 1986