Planck2013 results. VII. HFI time response and beams
Authors:
- Planck CollaborationPCPlanck Collaboration
- P. A. R. AdePAP. A. R. Ade
- F. Atrio-BarandelaFAF. Atrio-Barandela
- J. AumontJAJ. Aumont
- R. B. BarreiroRBR. B. Barreiro
Open Access
- 29 October 2014
- journal article
- research article
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 571, A7
Abstract
This paper characterizes the effective beams, the effective beam window functions and the associated errors for the Planck High Frequency Instrument (HFI) detectors. The effective beam is theangular response including the effect of the optics, detectors, data processing and the scan strategy. The window function is the representation of this beam in the harmonic domain which is required to recover an unbiased measurement of the cosmic microwave background angular power spectrum. The HFI is a scanning instrument and its effective beams are the convolution of: a) the optical response of the telescope and feeds; b) the processing of the time-ordered data and deconvolution of the bolometric and electronic transfer function; and c) the merging of several surveys to produce maps. The time response transfer functions are measured using observations of Jupiter and Saturn and by minimizing survey difference residuals. The scanning beam is the post-deconvolution angular response of the instrument, and is characterized with observations of Mars. The main beam solid angles are determined to better than 0.5% at each HFI frequency band. Observations of Jupiter and Saturn limit near sidelobes (within 5°) to about 0.1% of the total solid angle. Time response residuals remain as long tails in the scanning beams, but contribute less than 0.1% of the total solid angle. The bias and uncertainty in the beam products are estimated using ensembles of simulated planet observations that include the impact of instrumental noise and known systematic effects. The correlation structure of these ensembles is well-described by five error eigenmodes that are sub-dominant to sample variance and instrumental noise in the harmonic domain. A suite of consistency tests provide confidence that the error model represents a sufficient description of the data. The total error in the effective beam window functions is below 1% at 100 GHz up to multipole ℓ ~ 1500, and below 0.5% at 143 and 217 GHz up to ℓ ~ 2000.Keywords
All Related Versions
This publication has 69 references indexed in Scilit:
- FAST PIXEL SPACE CONVOLUTION FOR COSMIC MICROWAVE BACKGROUND SURVEYS WITH ASYMMETRIC BEAMS AND COMPLEX SCAN STRATEGIES: FEBeCoPThe Astrophysical Journal Supplement Series, 2011
- SEVEN-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE ( WMAP ) OBSERVATIONS: SKY MAPS, SYSTEMATIC ERRORS, AND BASIC RESULTSThe Astrophysical Journal Supplement Series, 2011
- SEVEN-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE ( WMAP ) OBSERVATIONS: PLANETS AND CELESTIAL CALIBRATION SOURCESThe Astrophysical Journal Supplement Series, 2011
- Planckpre-launch status: The HFI instrument, from specification to actual performanceAstronomy & Astrophysics, 2010
- Multi-mode horn design and beam characteristics for the Planck satelliteJournal of Instrumentation, 2010
- Measuring Planck beams with planetsAstronomy & Astrophysics, 2010
- A simulation pipeline for the Planck missionAstronomy & Astrophysics, 2005
- HEALPix: A Framework for High‐Resolution Discretization and Fast Analysis of Data Distributed on the SphereThe Astrophysical Journal, 2005
- Fast convolution on the spherePhysical Review D, 2001
- Response to deSouza et al.Endoscopy, 1996