Flow sensors found in animals often feature soft and slender structures (e.g. fish neuromasts, insect hairs, mammalian stereociliary bundles, etc) that bend in response to the slightest flow disturbances in their surroundings and heighten the animal’s vigilance with respect to prey and/or predators. However, fabrication of bioinspired flow sensors that mimic the material properties (e.g. low elastic modulus) and geometries (e.g. high-aspect ratio (HAR) structures) of their biological counterparts remains a challenge. In this work, we develop a facile and low-cost method of fabricating HAR cantilever flow sensors inspired by the mechanotransductory flow sensing principles found in nature. The proposed workflow entails high-resolution 3D printing to fabricate the master mould, replica moulding to create HAR polydimethylsiloxane (PDMS) cantilevers (thickness = 0.5–1 mm, width = 3 mm, aspect ratio = 20) with microfluidic channel (150 μm wide × 90 μm deep) imprints, and finally graphene nanoplatelet ink drop-casting into the microfluidic channels to create a piezoresistive strain gauge near the cantilever’s fixed end. The piezoresistive flow sensors were tested in controlled airflow (0–9 m s−1) inside a wind tunnel where they displayed high sensitivities of up to 5.8 kΩ m s−1, low hysteresis (11% of full-scale deflection), and good repeatability. The sensor output showed a second order dependence on airflow velocity and agreed well with analytical and finite element model predictions. Further, the sensor was also excited inside a water tank using an oscillating dipole where it was able to sense oscillatory flow velocities as low as 16–30 μm s−1 at an excitation frequency of 15 Hz. The methods presented in this work can enable facile and rapid prototyping of flexible HAR structures that can find applications as functional biomimetic flow sensors and/or physical models which can be used to explain biological phenomena.Keywords
Funding Information
- ITEA (ITEA-2018-17030-Daytime)
This publication has 29 references indexed in Scilit:
- A Novel Class of Strain Gauges Based on Layered Percolative Films of 2D MaterialsNano Letters, 2012
- A review on stereolithography and its applications in biomedical engineeringBiomaterials, 2010
- Why do insects have such a high density of flow-sensing hairs? Insights from the hydromechanics of biomimetic MEMS sensorsJournal of The Royal Society Interface, 2010
- An all-polymer airflow sensor using a piezoresistive composite elastomerSmart Materials and Structures, 2009
- A MEMS-Based Flow Rate and Flow Direction Sensing Platform with Integrated Temperature Compensation SchemeSensors, 2009
- Biologically inspired design of hydrogel-capped hair sensors for enhanced underwater flow detectionSoft Matter, 2008
- Artificial sensory hairs based on the flow sensitive receptor hairs of cricketsJournal of Micromechanics and Microengineering, 2005
- Design and fabrication of artificial lateral line flow sensorsJournal of Micromechanics and Microengineering, 2002
- Plastic deformation magnetic assembly (PDMA) of out-of-plane microstructures: Technology and applicationJournal of Microelectromechanical Systems, 2001
- Frequency response of the lateral-line organ of xenopus laevisPflügers Archiv - European Journal of Physiology, 1978