Myocardial perfusion MRI with an undersampled 3D stack‐of‐stars sequence
Authors:
- Ganesh AdluruGAGanesh Adluru
- Matthias C. SchabelMSMatthias C. Schabel
- Chris J. McGannCMChris J. McGann
- Edward V. R. DiBellaEDEdward V. R. DiBella
- 1 August 2012
- journal article
- Published by Wiley in Medical Physics
- Vol. 39 (8) , 5204-5211
Abstract
Purpose: To determine the feasibility of three‐dimensional (3D) hybrid radial (stack‐of‐stars) MRI with spatiotemporal total variation (TV) constrained reconstruction for dynamic contrast enhanced myocardial perfusion imaging.Methods: An ECG‐triggered saturation recovery turboFLASH sequence with undersampled stack‐of‐stars sampling with spatiotemporal TV constrained reconstruction was developed for dynamic contrast enhanced myocardial perfusion imaging. Simulations were performed to study the dependence of the approach to steady state on flip angle and saturation recovery time for this stack‐of‐stars acquisition. Phantom studies were used to show the effect of the flip angle selection and imperfect spoiling on image qualities. Studies were done in three humans to test the feasibility of the approach for myocardial perfusion imaging.Results: The simulation and phantom studies showed that imperfect spoiling and magnetization changes during the readout were a function of flip angle and nonoptimized selection of flip angle could degrade the images. Low flip angle acquisitions in the human subjects result in images with good quality similar to multislice radial 2D images.Conclusions: 3D stack‐of‐stars sampling with spatiotemporal TV constrained reconstruction provides a promising alternative for myocardial perfusion imaging.Keywords
Funding Information
- National Institutes of Health (R01EB006155)
This publication has 35 references indexed in Scilit:
- Myocardial first‐pass perfusion: Influence of spatial resolution and heart rate on the dark rim artifactMagnetic Resonance in Medicine, 2011
- Effect of improving spatial or temporal resolution on image quality and quantitative perfusion assessment with k‐t SENSE acceleration in first‐pass CMR myocardial perfusion imagingMagnetic Resonance in Medicine, 2010
- k‐t‐space accelerated myocardial perfusionJournal of Magnetic Resonance Imaging, 2008
- Dynamic contrast‐enhanced myocardial perfusion MRI accelerated with k‐t senseMagnetic Resonance in Medicine, 2007
- Myocardial First Pass Perfusion Imaging With GadobutrolInvestigative Radiology, 2007
- Parallel imaging for first-pass myocardial perfusionMagnetic Resonance Imaging, 2007
- Contrast-Enhanced First-Pass Myocardial Perfusion Magnetic Resonance Imaging With Parallel Acquisition at 3.0 TeslaInvestigative Radiology, 2007
- On the dark rim artifact in dynamic contrast‐enhanced MRI myocardial perfusion studiesMagnetic Resonance in Medicine, 2005
- Magnetic resonance first-pass myocardial perfusion imaging: Clinical validation and future applicationsJournal of Magnetic Resonance Imaging, 1999
- Technical note—Approach to myocardial perfusion with echo planar imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 1996