A Novel Sutureless Integrated Stented (SIS) Graft Prosthesis for Type A Aortic Dissection: A Pilot Study for a Prospective, Multicenter Clinical Trial
Authors:
Open Access
- 8 February 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 8, 806104
Abstract
Aims: Various kinds of surgical strategies and prostheses have been advocated to improve short-term and long-term outcomes in type A aortic dissection (TAAD). Large-scale repair of the pathological aorta is hard to generalize due to complex procedures. We aimed to investigate the performance, effectiveness and safety of a novel Sutureless Integrated Stented (SIS) graft prosthesis in TAAD patients undergoing total arch replacement (TAR) and frozen elephant trunk (FET) implantation surgery.Methods: All patients admitted to Fuwai Hospital were prospectively screened. Urgent or scheduled surgery was arranged for eligible patients. The primary endpoint was operative mortality. Key secondary endpoints included stroke, spinal cord injury, unexpected aortic reoperation, and 1-year survival. Discharged patients were followed up with computed tomography angiography and transthoracic echocardiography at 3 months, 6 months, and 1 year after surgery. Performance, effectiveness and safety analyses were performed in those patients.Results: Between August 1 and September 3, 2020, ten TAAD patients were enrolled in this study and successfully implanted with the SIS graft prosthesis. The median (IQR) age was 56.50 (43.75, 66.75) years (range from 31 to 75), and seven patients were male (70.0%). All patients underwent ascending aorta replacement + TAR + FET and additional procedures when necessary. The median (IQR) operation time, cardiopulmonary bypass time and cross clamp time were 270.50 (218.50, 312.50), 110.00 (88.00, 125.75), 69.50 (51.25, 82.75) min, respectively. Of note, the median (IQR) circulatory arrest time was 9.00 (8.00, 9.00) min (range from 4 to 12). The median (IQR) lowest nasopharyngeal temperature was 26.75 (25.98, 27.67) °C. Follow-up was 100% completed. During the 1-year follow-up, no patients died, no severe adverse events occurred, and rate of freedom from aortic reintervention was 100%.Conclusions: The SIS graft prosthesis was implanted in a novel sutureless way, which simplified the surgical procedure, shortened the circulatory arrest time and avoided deep hypothermia. The preliminary clinical outcomes and follow-up outcomes demonstrated the effectiveness and safety of this prosthesis. A large-scale trial is being conducted to further assess these findings.Keywords
Funding Information
- Beijing Science and Technology Planning Project (Z191100007619042)
This publication has 52 references indexed in Scilit:
- Thoracic stent graft sizing for frozen elephant trunk repair in acute type A dissectionThe Journal of Thoracic and Cardiovascular Surgery, 2013
- Section 2: AKI DefinitionKidney International Supplements, 2012
- International Standards for Neurological Classification of Spinal Cord Injury, Revised 2011Topics in Spinal Cord Injury Rehabilitation, 2012
- The Frozen Elephant Trunk for the Treatment of Chronic Dissection of the Thoracic Aorta: A Multicenter ExperienceThe Annals of Thoracic Surgery, 2011
- Complex thoracic aortic disease: Single-stage procedure with the frozen elephant trunk techniqueThe Journal of Thoracic and Cardiovascular Surgery, 2010
- Reporting standards for thoracic endovascular aortic repair (TEVAR)Journal of Vascular Surgery, 2010
- Antegrade Delivery of Stent Grafts to Treat Complex Thoracic Aortic DiseaseThe Annals of Thoracic Surgery, 2010
- Long-term results of the frozen elephant trunk technique for extended aortic arch diseaseEuropean Journal of Cardio-Thoracic Surgery, 2010
- Treatment of complex disease of the thoracic aorta: the frozen elephant trunk technique with the E-vita open prosthesis☆European Journal of Cardio-Thoracic Surgery, 2009
- Should the “elephant trunk” be skeletonized? Total arch replacement combined with stented elephant trunk implantation for Stanford type A aortic dissectionThe Journal of Thoracic and Cardiovascular Surgery, 2006