A Nonlinearized Multivariate Dominant Factor–Based Partial Least Squares (PLS) Model for Coal Analysis by Using Laser-Induced Breakdown Spectroscopy
Authors:
- 1 March 2013
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 67 (3) , 291-300
Abstract
A nonlinearized multivariate dominant factor–based partial least-squares (PLS) model was applied to coal elemental concentration measurement. For C concentration determination in bituminous coal, the intensities of multiple characteristic lines of the main elements in coal were applied to construct a comprehensive dominant factor that would provide main concentration results. A secondary PLS thereafter applied would further correct the model results by using the entire spectral information. In the dominant factor extraction, nonlinear transformation of line intensities (based on physical mechanisms) was embedded in the linear PLS to describe nonlinear self-absorption and inter-element interference more effectively and accurately. According to the empirical expression of self-absorption and Taylor expansion, nonlinear transformations of atomic and ionic line intensities of C were utilized to model self-absorption. Then, the line intensities of other elements, O and N, were taken into account for inter-element interference, considering the possible recombination of C with O and N particles. The specialty of coal analysis by using laser-induced breakdown spectroscopy (LIBS) was also discussed and considered in the multivariate dominant factor construction. The proposed model achieved a much better prediction performance than conventional PLS. Compared with our previous, already improved dominant factor–based PLS model, the present PLS model obtained the same calibration quality while decreasing the root mean square error of prediction (RMSEP) from 4.47 to 3.77%. Furthermore, with the leave-one-out cross-validation and L-curve methods, which avoid the overfitting issue in determining the number of principal components instead of minimum RMSEP criteria, the present PLS model also showed better performance for different splits of calibration and prediction samples, proving the robustness of the present PLS model.Keywords
This publication has 36 references indexed in Scilit:
- Multivariate Analysis of Laser-Induced Breakdown Spectroscopy Spectra of Soil SamplesSoil Science, 2010
- Sensitive detection of metals in water using laser-induced breakdown spectroscopy on wood sample substratesApplied Optics, 2010
- Laser-Induced Breakdown Spectroscopy Microanalysis of Trace Elements in Homo Sapiens TeethApplied Spectroscopy, 2010
- Laser-Induced Breakdown Spectroscopy of Steel: A Comparison of Univariate and Multivariate Calibration MethodsApplied Spectroscopy, 2010
- Novel Multivariate Analysis for Soil Carbon Measurements Using Laser‐Induced Breakdown SpectroscopySoil Science Society of America Journal, 2010
- Semi-quantitative analysis of metal alloys, brass and soil samples by calibration-free laser-induced breakdown spectroscopy: recent results and considerationsJournal of Analytical Atomic Spectrometry, 2009
- A Complementary Metal Oxide Semiconductor sensor array based detection system for Laser Induced Breakdown Spectroscopy: Evaluation of calibration strategies and application for manganese determination in steelSpectrochimica Acta Part B: Atomic Spectroscopy, 2008
- Laser-induced breakdown spectroscopy for quantitative spectrochemical analysis of geological materials: Effects of the matrix and simultaneous determinationAnalytica Chimica Acta, 2006
- Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphereSpectrochimica Acta Part B: Atomic Spectroscopy, 2006
- On-Line Sorting of Wood Treated with Chromated Copper Arsenate Using Laser-Induced Breakdown SpectroscopyApplied Spectroscopy, 2002