Measurement of hemoglobin saturation by oxygen in children and adolescents with sickle cell disease
Authors:
- 6 December 1999
- journal article
- clinical trial
- Published by Wiley in Pediatric Pulmonology
- Vol. 28 (6) , 423-428
Abstract
Pulse oximetry is a noninvasive method of measuring oxyhemoglobin saturation. The validity of pulse oximetry in sickle cell disease (SCD) has been questioned. We evaluated pulse oximetry, arterial blood gas analysis, and co‐oximetry in patients with SCD, and we assessed the effect of dyshemoglobin and altered blood‐oxygen affinity on their accuracy. Sixteen patients with SCD aged 7–21 years had arterial and venous blood drawn and transcutaneous pulse oximetry performed. Oxyhemoglobin dissociation curves were plotted from the venous blood of 15 patients. Oxyhemoglobin saturation estimated by arterial blood gas analysis (SaO2) and measured by pulse oximetry (SpO2) were both higher than the saturation by co‐oximetry (FO2Hb) (mean ± SD = 96.3 ± 1.6%, 94 ± 3.1%, and 89.1 ± 3.8%, respectively). There was a significant, positive correlation between SpO2 and FO2Hb (r = 0.7, P = 0.002). The patients had elevated levels of methemoglobin (MetHb) and carboxyhemoglobin (COHb) (2.3 ± 1.4% and 4.7 ± 1.3%, respectively). The oxyhemoglobin dissociation curves were frequently shifted to the right with oxygen tensions elevated when hemoglobin was 50% saturated with oxygen (P50) (32.5 ± 4.5 mm Hg). There was a strong correlation between the amounts of dyshemoglobin (MetHb + COHb) and the difference between SaO2 and FO2Hb (r = 0.7, P = 0.002). There was no correlation between the difference between SaO2 and FO2Hb and the P50 (r = 0.27, P = 0.33) There was also a strong positive correlation between SaO2‐SpO2 and dyshemoglobin fraction (r = 0.77, P = 0.001). We conclude that pulse oximetry and arterial blood gas analysis overestimate oxygen saturation when compared to co‐oximetry, but that SpO2 is consistently closer than SaO2 to FO2Hb. SpO2 is partially affected by MetHb and COHb. The discrepancy between SaO2 and FO2Hb is due to the presence of dyshemoglobin and a shifted oxyhemoglobin dissociation curve, but the effect from dyshemoglobin predominates. Pediatr Pulmonol. 1999;28:423–428.Keywords
This publication has 18 references indexed in Scilit:
- Respiratory Function of HemoglobinNew England Journal of Medicine, 1998
- Evaluation of pulse oximetry in sickle cell anemia patients presenting to the emergency department in acute vasoocclusive crisisThe American Journal of Emergency Medicine, 1996
- Comparison of oxygenation measurements in pediatric patients during sickle cell crisesThe Journal of Pediatrics, 1994
- Alveolar-arterial oxygen gradient in acute chest syndrome of sickle cell diseaseThe Journal of Pediatrics, 1993
- Pathogenesis of Lung Disease in Sickle HemoglobinopathiesAmerican Review of Respiratory Disease, 1993
- Pulse oximetry in sickle cell disease.Archives of Disease in Childhood, 1993
- Reliability of Noninvasive Oximetry in Black Subjects during Exercise and HypoxiaAmerican Review of Respiratory Disease, 1991
- Bias and Precision of Pulse Oximeters and Arterial OximetersChest, 1988
- OXYGEN DISSOCIATION CURVES IN SICKLE CELL ANEMIA AND IN SUBJECTS WITH THE SICKLE CELL TRAITJournal of Clinical Investigation, 1955
- THE DETERMINATION OF GASES IN BLOOD AND OTHER SOLUTIONS BY VACUUM EXTRACTION AND MANOMETRIC MEASUREMENT. IJournal of Biological Chemistry, 1924