Abstract
Damage accumulation in the cement mantle and debonding of the bone–cement interface are basic events that contribute to the long-term failure of cemented hip reconstructions. In this work, a numerical study with these two process coupled is presented. Previously uniform bone–cement interface mechanical properties were only considered. In this work, a new approach assuming nonuniform and random bone–cement interface mechanical properties was applied to investigate its effect on cement degradation. This methodology was also applied to simulate and compare the degradation process of the cement and bone–cement interface in three different concepts of design: Exeter, Charnley, and ABG II stems. Nonuniform and random mechanical properties of the bone–cement interface implied a simulation closer to reality. The predicted results showed that the cement deterioration and bone–cement interface debonding is different for each implant depending on the stem geometry. Lower cement deterioration was obtained for the Charnley stem and lower bone–cement interface debonding was predicted for the Exeter stem, while the highest deterioration (cement and bone–cement interface) was produced for the ABG II stem.Keywords
This publication has 55 references indexed in Scilit:
- Fixation of the Cemented Stem: Clinical Relevance of the Porosity and Thickness of the Cement MantleThe Open Orthopaedics Journal, 2009
- Does Increased Bone–Cement Interface Strength have Negative Consequences for Bulk Cement Integrity? A Finite Element StudyAnnals of Biomedical Engineering, 2008
- Determination of interfacial fracture toughness of bone–cement interface using sandwich Brazilian disksEngineering Fracture Mechanics, 2007
- Nano-mechanics of bone and bioactive bone cement interfaces in a load-bearing modelBiomaterials, 2006
- Analysis of the debonding of the stem–cement interface in intramedullary fixation using a non-linear fracture mechanics approachEngineering Fracture Mechanics, 2005
- Bone remodelling simulation: a tool for implant designComputational Materials Science, 2002
- Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cementJournal of Biomechanics, 1997
- Coulomb frictional interfaces in modeling cemented total hip replacements: A more realistic modelJournal of Biomechanics, 1995
- A Model of Tension and Compression Cracks With Cohesive Zone at a Bone-Cement InterfaceJournal of Biomechanical Engineering, 1985
- A Continuous Damage Mechanics Model for Ductile FractureJournal of Engineering Materials and Technology, 1985