MRI as a one-stop destination for evaluation of CSF shunt malfunction
Open Access
- 3 March 2023
- journal article
- research article
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 54 (1) , 1-15
Abstract
Background: Despite the high-frequency rate of cerebrospinal fluid shunt malfunction, radiological evaluation of CSF shunts has remained deficient, focusing mainly on demonstrating secondary signs of shunt failure rather than evaluating the shunt tube itself. We aimed to study the utility of different MR pulse sequences in evaluating the cranial and abdominal ends of CSF shunts in order to identify the potential cause of shunt failure and its impact on patient management. Results: Twenty-five patients (18 males, 7 females, median age 2.5 years, IQR 0.75–15) were enrolled in the study, having 28 ventriculo-peritoneal shunts and single ventriculo-gallbladder shunt. The catheter lumen and fine intraventricular septae were only demonstrated in 3D-DRIVE sequences (p < 0.001). Except for three patients (having cranial end-related complications), all patients with cranial and/or abdominal end-related complications received surgery (p < 0.001, positive likelihood and negative likelihood ratios = 7.27, 0.3, respectively, sensitivity = 0.7 and specificity = 0.9). MRI findings (luminal occlusion, disconnection, CSF collection, or migration) were consistent with operative data. There is no significant difference between patients who underwent surgery and those with conservative management, or symptomatic and asymptomatic patients in terms of the prevalence of ventricular dilatation or white matter signal abnormality. The results of the abdomino-pelvic fat-suppressed T2-WI showed excellent agreement with ultrasound findings (Cohen’s Kappa 0.9). Quantitative PC could give insights into CSF dynamics, which depend on the site and cause of shunt malfunction. Conclusions: MRI could be a one-stop destination for evaluating patients with suspected non-acute shunt malfunction. It was found to have clinical relevance in terms of accurately locating the exact site and possible cause of shunt-related complications.Keywords
This publication has 47 references indexed in Scilit:
- Detection of ventricular shunt malfunction in the ED: relative utility of radiography, CT, and nuclear imagingEmergency Radiology, 2011
- A novel solution to reduce the complications of distal shunt catheter displacement associated with obesityJournal of Neurosurgery, 2010
- Subcutaneous Migration of Distal Ventriculoperitoneal Shunt Catheter Caused by Abdominal Fat Pad Shift -Three Case Reports-Neurologia medico-chirurgica, 2010
- Intraabdominal Complications Secondary to Ventriculoperitoneal Shunts: CT Findings and Review of the LiteratureAmerican Journal of Roentgenology, 2009
- Retrieval of ventricular catheter with the aid of endoscopyJournal of neurosurgery. Pediatrics, 2008
- The utility of the plain radiograph “shunt series” in the evaluation of suspected ventriculoperitoneal shunt failure in pediatric patientsPediatric Radiology, 2007
- Yield and utility of radiographic “shunt series” in the evaluation of ventriculo-peritoneal shunt malfunction in adult emergency patientsEmergency Radiology, 2007
- Sterile ascites from a ventriculoperitoneal shunt: a case report and review of the literatureChild's Nervous System, 2006
- Failure rate of frontal versus parietal approaches for proximal catheter placement in ventriculoperitoneal shunts: revisitedJournal of Clinical Neuroscience, 2005
- Intracranial hemorrhage: ultrasound, CT and MRI findingsEuropean Radiology, 2005