Integration of neuraminidase inhibitor assay into a single-step operation using a combinable poly(dimethylsiloxane) capillary sensor
- 18 March 2013
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (11) , 3158-3162
Abstract
The conventional neuraminidase inhibitor assay requiring complicated step-by-step operations was successfully integrated into a “single step” operation using a combinable poly(dimethylsiloxane) (PDMS) capillary (CPC) sensor. In the conventional neuraminidase inhibitor assay, complicated step-by-step operations including initial reaction of an inhibitor and an enzyme, and subsequent reaction with a fluorescent substrate are necessary. Furthermore, optimal pH conditions for the enzymatic reaction differ from those of fluorescence detection. Therefore, preparation of different pH buffer solutions is also essential. To simplify the neuraminidase inhibitor assay into a single-step operation, we applied our recently developed CPC sensor array. Because the CPC sensor allows independent immobilization of different reagents, such as enzymes and fluorescent substrates, simple introduction of an inhibitor solution by capillary action leads to fluorescence emissions. Here, we investigated the optimal pH that enables us to perform the neuraminidase inhibitor assay via a single step operation using the CPC sensor. When the reaction profile was investigated under the optimal pH, the total reaction time was shortened from 1 h to 15 min. Moreover, the neuraminidase inhibitor assay was validated using a typical inhibitor, N-acetyl-2,3-dehydro-2-deoxyneuraminic acid. The inhibition constant, Ki, which was calculated on the basis of the IC50 obtained from the inhibition curve, was in good agreement with the published values. Furthermore, we demonstrated a comparison of fluorescence responses for buffer solutions versus the solution of a well-known influenza drug, Relenza. We observed successful inhibition by Relenza. In addition to the CPC-based approach, the consumption of enzyme, substrate, and inhibitor was reduced to 1% of the amount used in conventional neuraminidase inhibitor assays.Keywords
This publication has 26 references indexed in Scilit:
- Droplet-Based Microfluidic Flow Injection System with Large-Scale Concentration Gradient by a Single Nanoliter-Scale Injection for Enzyme Inhibition AssayAnalytical Chemistry, 2011
- Reagent-release capillary array-isoelectric focusing device as a rapid screening device for IEF condition optimizationLab on a Chip, 2010
- An automated two-phase microfluidic system for kinetic analyses and the screening of compound librariesLab on a Chip, 2010
- Ensemble-Based Virtual Screening Reveals Potential Novel Antiviral Compounds for Avian Influenza NeuraminidaseJournal of Medicinal Chemistry, 2008
- High-throughput screening of enzyme inhibition using an inhibitor gradient generated in a microchannelLab on a Chip, 2007
- Integration of Multianalyte Sensing Functions on a Capillary-Assembled Microchip: Simultaneous Determination of Ion Concentrations and Enzymatic Activities by a “Drop-and-Sip” TechniqueAnalytical Chemistry, 2006
- Integration of multiple-ion-sensing on a capillary-assembled microchipAnalytica Chimica Acta, 2006
- Analysis of inhibitor binding in influenza virus neuraminidaseProtein Science, 2001
- Purification and Characterization of Neuraminidase from Clostridium perfringensHoppe-Seyler´s Zeitschrift Für Physiologische Chemie, 1975
- Relationship between the inhibition constant (KI) and the concentration of inhibitor which causes 50 per cent inhibition (I50) of an enzymatic reactionBiochemical Pharmacology, 1973