Abstract
The elimination of position sensors allows sensorless control to minimizing the size, cost, and additional layers of the permanent magnet synchronous motor (PMSM). In this work, a new flux estimator with an active disturbance rejection controller (ADRC) drift-elimination capability is developed in order to accomplish precise flux estimation. The ESO integrated into the ADRC is capable of detecting and compensating each of the inner model’s fluctuation along with external loads disturbances, enabling a control system with a more effective dynamic response and robust regulations. As a result, the drift issue is greatly mitigated, and the stator flux is accurately predicted throughout a broad range of speeds. The proposed flux observer is validated via sensorless speed vector control of a 15 kW IPMSM motor.

This publication has 12 references indexed in Scilit: