Abstract
Materials with high dielectric constant (HDC) have been used in high field MRI to decrease specific absorption rate (SAR), increase magnetic field intensity, and increase signal-to-noise ratio. In previous studies, the HDC materials were placed inside the RF coil decreasing the space available. This study describes an alternative approach that considers an HDC-based sleeve placed outside the RF coil. The effects of an HDC on the electromagnetic (EM) field were studied using numerical simulations with a coil unloaded and loaded with a human head model. In addition, experimental EM measurements at 128 MHz were performed inside a custom-made head coil, fitted with a distilled water sleeve. The numerical simulations showed up to 40% decrease in maximum 10 g-avg. SAR on the surface of the head model with an HDC material of barium titanate. Experimental measurements also showed up to 20% decrease of maximum electric field using an HDC material of distilled water. The proposed method can be incorporated in the design of high field transmit RF coils.Keywords
Funding Information
- FDA Center of Devices
- Radiological Health Critical Path Program
This publication has 18 references indexed in Scilit:
- Radiofrequency field enhancement with high dielectric constant (HDC) pads in a receive array coil at 3.0TJournal of Magnetic Resonance Imaging, 2013
- Dielectric materials in magnetic resonanceConcepts in Magnetic Resonance Part A, 2011
- Improvements in high‐field localized MRS of the medial temporal lobe in humans using new deformable high‐dielectric materialsNMR in Biomedicine, 2010
- Reducing SAR and enhancing cerebral signal‐to‐noise ratio with high permittivity padding at 3 TMagnetic Resonance in Medicine, 2010
- Faraday shields within a solenoidal coil to reduce sample heating: Numerical comparison of designs and experimental verificationJournal of Magnetic Resonance, 2010
- The Virtual Family—development of surface-based anatomical models of two adults and two children for dosimetric simulationsPhysics in Medicine & Biology, 2009
- Dielectric inserts for sensitivity and RF magnetic field enhancement in NMR volume coilsJournal of Magnetic Resonance, 2009
- A method to separate conservative and magnetically-induced electric fields in calculations for MRI and MRS in electrically-small samplesJournal of Magnetic Resonance, 2009
- Spatial resolution of numerical models of man and calculated specific absorption rate using the FDTD method: A study at 64 MHz in a magnetic resonance imaging coilJournal of Magnetic Resonance Imaging, 2003
- Admittance models for open ended coaxial probes and their place in dielectric spectroscopyPhysics in Medicine & Biology, 1994