Watch-PAT is Useful in the Diagnosis of Sleep Apnea in Patients with Atrial Fibrillation
Open Access
- 1 December 2020
- journal article
- research article
- Published by Taylor & Francis in Nature and Science of Sleep
- Vol. ume 12, 1115-1121
Abstract
Background: Early diagnosis and treatment of sleep apnea in patients with atrial fibrillation (AF) is critical. The WatchPAT (WP) device was shown to be accurate for the diagnosis of sleep apnea; however, studies using the WatchPAT device have thus far excluded patients with arrhythmias due to the potential effect of arrhythmias on the peripheral arterial tonometry (PAT) amplitude and pulse rate changes. Purpose: To examine the accuracy of the WP in detecting sleep apnea in patients with AF. Patients and Methods: Patients with AF underwent simultaneous WP and PSG studies in 11 sleep centers. PSG scoring was blinded to the automatically analyzed WP data. Results: A total of 101 patients with AF (70 males) were recruited. Forty-six had AF episodes during the overnight sleep study. A significant correlation was found between the PSG-derived AHI and the WP- derived AHI (r=0.80, p< 0.0001). There was a good agreement between PSG-derived AHI and WP-derived AHI (mean difference of AHI: -0.02± 13.2). Using a threshold of AHI ≥ 15 per hour of sleep, the sensitivity and specificity of the WP were 0.88 and 0.63, respectively. The overall accuracy in sleep staging between WP and PSG was 62% with Kappa agreement of 0.42. Conclusion: WP can detect sleep apnea events in patients with AF. AF should not be an exclusion criterion for using the device. This finding may be of even greater importance in the era of the COVID19 epidemic, when sleep labs were closed and most studies were home based.Keywords
This publication has 32 references indexed in Scilit:
- Arousal from sleep: implications for obstructive sleep apnea pathogenesis and treatmentJournal of Applied Physiology, 2014
- Effect of Sleep Apnea and Continuous Positive Airway Pressure on Cardiac Structure and Recurrence of Atrial FibrillationJournal of the American Heart Association, 2013
- Relation of the Severity of Obstructive Sleep Apnea in Response to Anti-Arrhythmic Drugs in Patients With Atrial Fibrillation or Atrial FlutterThe American Journal of Cardiology, 2012
- Sleep Staging Based on Autonomic Signals: A Multi-Center Validation StudyJournal of Clinical Sleep Medicine, 2011
- Validation study of portable device for the diagnosis of obstructive sleep apnea according to the new AASM scoring criteria: Watch-PAT 100Acta Oto-Laryngologica, 2010
- Baseline apnoea/hypopnoea index and high-sensitivity C-reactive protein for the risk of recurrence of atrial fibrillation after successful electrical cardioversion: a predictive model based upon the multiple effects of significant variablesEP Europace, 2009
- Prevalence of sleep disordered breathing in paroxysmal and persistent atrial fibrillation patients with normal left ventricular functionEuropean Heart Journal, 2008
- Detecting REM sleep from the finger: an automatic REM sleep algorithm based on peripheral arterial tone (PAT) and actigraphyPhysiological Measurement, 2006
- An automatic ambulatory device for detection of AASM defined arousals from sleep: the WP100Sleep Medicine, 2003
- Evaluation of a Portable Device Based on Peripheral Arterial Tone for Unattended Home Sleep StudiesaChest, 2003