Sensitivity evaluation and selective plane imaging geometry for x‐ray‐induced luminescence imaging
Open Access
- 13 July 2017
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 44 (10) , 5367-5377
Abstract
Purpose: X‐ray‐induced luminescence (XIL) is a hybrid x‐ray/optical imaging modality that employs nanophosphors that luminescence in response to x‐ray irradiation. X‐ray‐activated phosphorescent nanoparticles have potential applications in radiation therapy as theranostics, nanodosimeters, or radiosensitizers. Extracting clinically relevant information from the luminescent signal requires the development of a robust imaging model that can determine nanophosphor distributions at depth in an optically scattering environment from surface radiance measurements. The applications of XIL in radiotherapy will be limited by the dose‐dependent sensitivity at depth in tissue. We propose a novel geometry called selective plane XIL (SPXIL), and apply it to experimental measurements in optical gel phantoms and sensitivity simulations.Methods: An imaging model is presented based on the selective plane geometry which can determine the detected diffuse optical signal for a given x‐ray dose and nanophosphor distribution at depth in a semi‐infinite, optically homogenous material. The surface radiance in the model is calculated using an analytical solution to the extrapolated boundary condition. Y2O3:Eu3+ nanoparticles are synthesized and inserted into various optical phantom in order to measure the luminescent output per unit dose for a given concentration of nanophosphors and calibrate an imaging model for XIL sensitivity simulations. SPXIL imaging with a dual‐source optical gel phantom is performed, and an iterative Richardson–Lucy deconvolution using a shifted Poisson noise model is applied to the measurements in order to reconstruct the nanophosphor distribution.Results: Nanophosphor characterizations showed a peak emission at 611 nm, a linear luminescent response to tube current and nanoparticle concentration, and a quadratic luminescent response to tube voltage. The luminescent efficiency calculation accomplished with calibrated bioluminescence mouse phantoms determines 1.06 photons were emitted per keV of x‐ray radiation absorbed per g/mL of nanophosphor concentration. Sensitivity simulations determined that XIL could detect a concentration of 1 mg/mL of nanophosphors with a dose of 1 cGy at a depth ranging from 2 to 4 cm, depending on the optical parameters of the homogeneous diffuse optical environment. The deconvolution applied to the SPXIL measurements could resolve two sources 1 cm apart up to a depth of 1.75 cm in the diffuse phantom.Conclusions: We present a novel imaging geometry for XIL in a homogenous, diffuse optical environment. Basic characterization of Y2O3:Eu3+ nanophosphors are presented along with XIL/SPXIL measurements in optical gel phantoms. The diffuse optical imaging model is validated using these measurements and then calibrated in order to execute initial sensitivity simulations for the dose‐depth limitations of XIL imaging. The SPXIL imaging model is used to perform a deconvolution on a dual‐source phantom, which successfully reconstructs the nanophosphor distributions.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering
- National Institutes of Health (T32 EB002103, R01EB017293)
- National Cancer Institute (R01CA171785, P30 CA14599, S10 RRO21039, R01CA164492)
This publication has 36 references indexed in Scilit:
- Monitoring pH-Triggered Drug Release from Radioluminescent Nanocapsules with X-ray Excited Optical LuminescenceACS Nano, 2013
- Hybrid x‐ray/optical luminescence imaging: Characterization of experimental conditionsMedical Physics, 2010
- The two-photon excitation of SiO2-coated Y2O3:Eu3+ nanoparticles by a near-infrared femtosecond laserNanotechnology, 2008
- Tutorial on diffuse light transportJournal of Biomedical Optics, 2008
- In vivo imaging of light-emitting probesJournal of Biomedical Optics, 2001
- Compensation for readout noise in CCD imagesJournal of the Optical Society of America A, 1995
- Boundary conditions for the diffusion equation in radiative transferJournal of the Optical Society of America A, 1994
- Image recovery from data acquired with a charge-coupled-device cameraJournal of the Optical Society of America A, 1993
- An iterative technique for the rectification of observed distributionsThe Astronomical Journal, 1974
- Bayesian-Based Iterative Method of Image Restoration*Journal of the Optical Society of America, 1972