Initial clinical experience with the ADAPT technique: A direct aspiration first pass technique for stroke thrombectomy
Authors:
- 23 July 2018
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 10 (Suppl 1) , i20-i25
Abstract
Background The development of new revascularization devices has improved recanalization rates and time but not clinical outcomes. We report our initial results with a new technique utilizing a direct aspiration first pass technique with a large bore aspiration catheter as the primary method for vessel recanalization. Methods A retrospective evaluation of a prospectively captured database of 37 patients at six institutions was performed on patients where the ADAPT technique was utilized. The data represent the initial experience with this technique. Results The ADAPT technique alone was successful in 28 of 37 (75%) cases although six cases had large downstream emboli that required additional aspiration. Nine cases required the additional use of a stent retriever and one case required the addition of a Penumbra aspiration separator to achieve recanalization. The average time from groin puncture to at least Thrombolysis in Cerebral Ischemia (TICI) 2b recanalization was 28.1 min, and all cases were successfully revascularized. TICI 3 recanalization was achieved 65% of the time. On average, patients presented with an admitting National Institutes of Health Stroke Scale (NIHSS) score of 16.3 and improved to an NIHSS score of 4.2 by the time of hospital discharge. There was one procedural complication. Discussion This initial experience highlights the fact that the importance of the technique with which new stroke thrombectomy devices are used may be as crucial as the device itself. The ADAPT technique is a simple and effective approach to acute ischemic stroke thrombectomy. Utilizing the latest generation of large bore aspiration catheters in this fashion has allowed us to achieve excellent clinical and angiographic outcomes.Keywords
This publication has 19 references indexed in Scilit:
- An investigation of the cost and benefit of mechanical thrombectomy for endovascular treatment of acute ischemic strokeJournal of NeuroInterventional Surgery, 2013
- Solitaire flow restoration device versus the Merci Retriever in patients with acute ischaemic stroke (SWIFT): a randomised, parallel-group, non-inferiority trialThe Lancet, 2012
- Trevo versus Merci retrievers for thrombectomy revascularisation of large vessel occlusions in acute ischaemic stroke (TREVO 2): a randomised trialThe Lancet, 2012
- Merci Retrievers as Access Adjuncts for Reperfusion CathetersNeurosurgery, 2011
- The Penumbra Stroke System: a technical reviewJournal of NeuroInterventional Surgery, 2011
- Utilization of the Neuron 6 French 0.053 inch inner luminal diameter guide catheter for treatment of cerebral vascular pathology: continued experience with ultra distal access into the cerebral vasculatureJournal of NeuroInterventional Surgery, 2011
- Patient Outcomes With Endovascular Embolectomy Therapy for Acute Ischemic StrokeStroke, 2011
- The POST trial: initial post-market experience of the Penumbra system: revascularization of large vessel occlusion in acute ischemic stroke in the United States and EuropeJournal of NeuroInterventional Surgery, 2010
- INTRACRANIAL PLACEMENT OF A NEW, COMPLIANT GUIDE CATHETERNeurosurgery, 2008
- The Impact of Recanalization on Ischemic Stroke OutcomeStroke, 2007