On the Design and Response of Domestic Ground-Source Heat Pumps in the UK
Open Access
Abstract
The design and response of ground source heat pumps coupled to vertical closed loop arrays in UK domestic applications are investigated in this article. Two typical UK house types are selected as the vehicle for the study and a detailed dynamic thermal modelling method is used to arrive at time-series heating demands for the two houses. A new empirical heat pump model is derived using experimental data taking into account the deteriorating performance of the heat pump during periods of light load. The heat pump model is incorporated into an existing numerical ground model and completed with a classical effectiveness type heat exchange model of the closed loop array. The model is used to analyse array sizing and performance over an extended time period, as well as sensitivity of the design to soil conductivity and borehole heat exchanger resistance and sensitivity to over-sizing and part-load behavior of the heat pump. Results show that the UK’s standard for ground source design (the Microgeneration Certification Scheme) may lead to under-estimated array sizes and that heating system over-sizing and deleterious part-load heat pump performance can add up to 20% to the electrical consumption of these systems.Keywords
Funding Information
- None specific
This publication has 13 references indexed in Scilit:
- Meta-analysis of European heat pump field trial efficienciesEnergy and Buildings, 2013
- Power requirements of ground source heat pumps in a residential areaApplied Energy, 2013
- Experimental study on a monovalent inverter-driven water-to-water heat pump with a desuperheater for low energy housesApplied Thermal Engineering, 2013
- Experimental evaluation of a geothermal heat pump for space heating and domestic hot water simultaneous productionRenewable Energy, 2012
- Performance and control of domestic ground-source heat pumps in retrofit installationsEnergy and Buildings, 2011
- An investigation of the heat pump performance and ground temperature of a piled foundation heat exchanger system for a residential buildingEnergy, 2010
- Reversible heat pump model for seasonal performance optimizationEnergy and Buildings, 2010
- Implementation and Validation of Ground-Source Heat Pump System Models in an Integrated Building and System Simulation EnvironmentHVAC&R Research, 2006
- Modelling the robustness properties of HVAC plant under feedback controlBuilding Services Engineering Research & Technology, 2003
- Building thermal model reduction using nonlinear constrained optimizationBuilding and Environment, 2002