Multiband accelerated spin‐echo echo planar imaging with reduced peak RF power using time‐shifted RF pulses
Open Access
- 6 March 2013
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (5) , 1261-1267
Abstract
Purpose: To evaluate an alternative method for generating multibanded radiofrequency (RF) pulses for use in multiband slice‐accelerated imaging with slice‐GRAPPA unaliasing, substantially reducing the required peak power without bandwidth compromises. This allows much higher accelerations for spin‐echo methods such as SE‐fMRI and diffusion‐weighted MRI where multibanded slice acceleration has been limited by available peak power.Theory and Methods: Multibanded “time‐shifted” RF pulses were generated by inserting temporal shifts between the applications of RF energy for individual bands, avoiding worst‐case constructive interferences. Slice profiles and images in phantoms and human subjects were acquired at 3 T.Results: For typical sinc pulses, time‐shifted multibanded RF pulses were generated with little increase in required peak power compared to single‐banded pulses. Slice profile quality was improved by allowing for higher pulse bandwidths, and image quality was improved by allowing for optimum flip angles to be achieved.Conclusion: A simple approach has been demonstrated that significantly alleviates the restrictions imposed on achievable slice acceleration factors in multiband spin‐echo imaging due to the power requirements of multibanded RF pulses. This solution will allow for increased accelerations in diffusion‐weighted MRI applications where data acquisition times are normally very long and the ability to accelerate is extremely valuable. Magn Reson Med 69:1261–1267, 2013 Wiley Periodicals, Inc.Keywords
Funding Information
- NIH Biotechnology Research Center (BTRC) program (formerly P41 RR008079 from NCRR and currently P41 EB015894 from NIBIB)
- Human Connectome Project from 16 National Institutes of Health Institutes and Centers that support the NIH Blueprint for Neuroscience Research (1U54MH091657)
This publication has 28 references indexed in Scilit:
- Improving diffusion MRI using simultaneous multi-slice echo planar imagingNeuroImage, 2012
- Whole brain, high resolution spin-echo resting state fMRI using PINS multiplexing at 7TNeuroImage, 2012
- Temporally-independent functional modes of spontaneous brain activityProceedings of the National Academy of Sciences, 2012
- Local SAR in parallel transmission pulse designMagnetic Resonance in Medicine, 2011
- Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penaltyMagnetic Resonance in Medicine, 2011
- Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion ImagingPLOS ONE, 2010
- Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRIMagnetic Resonance in Medicine, 2010
- High-field fMRI unveils orientation columns in humansProceedings of the National Academy of Sciences, 2008
- Robust detection of ocular dominance columns in humans using Hahn Spin Echo BOLD functional MRI at 7 TeslaNeuroImage, 2007