Control Techniques for CRM-Based High-Frequency Soft-Switching Three-Phase Inverter Under Unbalanced Grid Conditions
- 11 January 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (6) , 6613-6624
Abstract
This article presents control techniques for the critical conduction mode(CRM) based high-frequency soft-switching three-phase inverter under unbalanced grid conditions. The soft-switching technique with silicon carbide (SiC) power devices allows the inverter to operate at hundreds of kHz with high efficiency and high power density. To extend the soft-switching technique to more practical cases, behaviors of the inverter under unbalanced grid conditions, specifically voltage sag, are investigated. During the voltage sag, the ac voltage at the grid becomes unbalanced. This requires unbalanced ac current reference to avoid output active power oscillation. With the unbalanced grid voltage and the ac current reference, the inverter loses the soft-switching capability. Continuous conduction mode (CCM) operation occurs where discontinuous conduction mode (DCM) operation is intended leading to large turn- on loss. To eliminate the CCM issue, two improved modulation techniques are proposed by using off -time extension in the CRM phase and by skipping pulses in the DCM phase. This article discusses how the CCM operation arises and details the proposed control methods. The performance of the proposed control is validated experimentally under a variety of grid imbalance cases with an SiC-based three-phase inverter prototype.Keywords
Funding Information
- Center for Power Electronics Systems
This publication has 26 references indexed in Scilit:
- Evaluation of commercial scale transformerless solar inverter technology2015
- Control Strategy to Maximize the Power Capability of PV Three-Phase Inverters During Voltage SagsIEEE Transactions on Power Electronics, 2015
- Variable boundary dual mode current modulation scheme for three-phase micro-inverter2014
- High-temperature characterization and comparison of 1.2 kV SiC power MOSFETs2013
- High efficiency current mode control for three-phase micro-inverters2012
- Impact of FERC 661-A and IEEE 1547 on Photovoltaic inverter design2011
- Flexible Active Power Control of Distributed Power Generation Systems During Grid FaultsIEEE Transactions on Industrial Electronics, 2007
- Advanced Grid Synchronization System for Power Converters under Unbalanced and Distorted Operating Conditions2006
- Overview of Control and Grid Synchronization for Distributed Power Generation SystemsIEEE Transactions on Industrial Electronics, 2006
- Improving voltage disturbance rejection for variable-speed wind turbinesIEEE Transactions on Energy Conversion, 2002