Coronary Calcium Scoring Using 16-Row Multislice Computed Tomography
Authors:
- Georg MühlenbruchGMGeorg Mühlenbruch
- Joachim E WildbergerJWJoachim E Wildberger
- Ralf KoosRKRalf Koos
- Marco DasMDMarco Das
- Thomas G FlohrTFThomas G Flohr
- Matthias NiethammerMNMatthias Niethammer
- Claudia WeissCWClaudia Weiss
- Rolf W GüntherRGRolf W Günther
- Andreas H MahnkenAMAndreas H Mahnken
- 1 March 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 40 (3) , 148-154
Abstract
We sought to assess the agreement of coronary artery calcium score in nonenhanced and contrast-enhanced multislice-spiral computed tomography. Vessel phantoms and 36 patients underwent nonenhanced and contrast-enhanced cardiac multislice-spiral computed tomography (Sensation 16; Siemens, Germany). Reconstruction-parameters: slice thickness 3 mm, increment 2 mm, kernels B35f and B30f. The Agatston score, calcium mass, and number of lesions were calculated. Images were scored using detection thresholds of 130 Hounsfield units (HU) and 350 HU. Based on the Agatston score, risk stratification was performed. In the phantom and patient study, altering the threshold from 130 to 350 HU led to a significant decrease in the mean Agatston score (phantom: 54.6%, patients: 66.7%) and calcium mass (33.0%, 47.0%) (B35f). Contrast-enhanced studies (threshold: 350 HU) showed an increase of the mean Agatston score (71.0%, 20.7%) and calcium mass (81.0%, 16.0%) when compared with nonenhanced scans (threshold: 350 HU). A total of 57% of all patients were assigned to different risk groups. Contrast material may simulate calcification; therefore, calculation of the coronary calcium score from contrast-enhanced images is not reliable.Keywords
This publication has 23 references indexed in Scilit:
- Reproducibility and Accuracy of Coronary Calcium Measurements with Multi–Detector Row versus Electron-Beam CTRadiology, 2002
- Coronary Artery Calcium MeasurementAmerican Journal of Roentgenology, 2001
- Evaluation of Subsecond Gated Helical CT for Quantification of Coronary Artery Calcium and Comparison with Electron Beam CTAmerican Journal of Roentgenology, 2000
- Comparison of electron beam computed tomography scanning and conventional risk factor assessment for the prediction of angiographic coronary artery diseaseJACC, 1998
- Electron Beam Computed Tomographic Coronary Calcium Score Cutpoints and Severity of Associated Angiographic Lumen StenosisJACC, 1997
- Coronary Artery Calcium Area by Electron-Beam Computed Tomography and Coronary Atherosclerotic Plaque AreaCirculation, 1995
- Quantification of coronary artery calcium using ultrafast computed tomographyJACC, 1990
- Coronary calcification in the diagnosis of coronary artery diseaseThe American Journal of Cardiology, 1979
- Incidence and significance of coronary artery calcification.Heart, 1974
- Significance of calcification of the coronary arteriesThe American Journal of Cardiology, 1970